321 Studios 7322 230 Start up / Stop the booster function, Starting-up, Pan detection, Action

Models: 7322 230

1 28
Download 28 pages 30.8 Kb
Page 20
Image 20

Starting-up

You must first start-up the hob, then the heating zone :

Start-up/ switch off the hob :

Action

Control panel

Display

To start

Press key [ 0/I ]

To stop

Press key [ 0/I ]

2 x [ 0 ] nothing or [ H ]

Start-up/ switch off the heating zone :

Action

Control panel

Display

Increase power

Press key [ + ]

[ 4

] to [ 9 ]

Decrease power

Press key [ - ]

[ 9

] to [ 1 ]

Stop

Press simultaneous[ + ] and [ - ]

[ 0

] or [ H ]

 

or press [ - ]

[ 0

] or [ H ]

If no setting are made in 20 seconds the hob return in waiting position.

Pan detection

The pan detection ensures a perfect safety.

The induction doesn’t work:

If there is no pan on the heating zone or if this pan is not adapted to the induction. In this case it is impossible to increase the power and the display shows [ U ]. This symbol disappears when a pan is put on the heating zone.

If the pan is removed from the heating zone the operation is stopped. The display shows [ U ]. The symbol [ U ] disappears when the pan is put back to the heating zone. The cooking continues with the power level chosen before.

Residual heat indication

After the switch-off of the hob, the heating zone is still hot and indicates [ H ] on the display. The symbol [ H ] disappears when the heating zone may be touched without danger.

As far as the residual heat indicator is on light, don’t touch the heating zone and don’t put any heat sensitive object on them. There are risks of burn and fire.

Booster function

The booster function [ P ] grants a boost of power to the selected heating zone.

If this function is activated the heating zones works during 10 minutes with an ultra high power. The booster is foreseen for example to heat up rapidly big quantities of water.

Start up / Stop the booster function :

Action

Increase power Start up the booster Stop the booster

Control panel

Display

Press key [ + ] or [ - ]

[ 1

] to [ 9 ]

Press key [ + ]

[ P ] for 10 min

Press key [ - ]

[ 9

]

7

Page 20
Image 20
321 Studios 7322 230 Start up / Stop the booster function, Starting-up, Pan detection, Residual heat indication, Action