Stacking Units | 27 |
Figure 8 A stack of two units
Stacking Up To Four You can stack up to four Switch units using a Switch 3300 MM and the Units appropriate number of Matrix Cables.
You need only one SuperStack II Switch 3300 MM per stack.
To stack up to four Switch units:
1
2Arrange the units as required. They can be
3Connect the Matrix Cables, as shown in Figure 9:
a Connect a Matrix Cable to the port marked Unit 2 on the
Switch 3300 MM. Connect the other end of this cable to the Matrix Port on the Switch placed immediately above the Switch 3300 MM.
b Connect a second Matrix Cable to the port marked Unit 3 on the Switch 3300 MM. Connect the other end of this cable to the Matrix Port on the next Switch up.
c Connect a third Matrix Cable to the port marked Unit 4 on the Switch 3300 MM. Connect the other end of this cable to the Matrix Port on the Switch at the top of the stack.