3Com S21x installation manual Power Up, Sequence, Stage When This indicates

Models: S21x

1 66
Download 66 pages 16.98 Kb
Page 38
Image 38

Powerup Diagnostics

Power Up

When the PathBuilder S21x switch power cord is plugged into the power supply

Sequence

outlet, you will see the following powerup sequence:

 

 

 

 

 

Stage

when...

...this indicates

 

 

 

 

 

1

POWER (GREEN) lights

PathBuilder S200 series switch is

 

 

turns on.

receiving power.

 

 

 

 

 

2

TEST (GREEN) comes on

Diagnostics executes for 30 seconds.

 

 

and blinks five times

 

 

 

 

 

 

3

STATUS (GREEN) comes on

Indicates software is being downloaded

 

 

and blinks at slow rate.

from FLASH.

 

 

TEST/WATCHDOG

 

 

 

(ORANGE) light also remain

 

 

 

on.

 

 

 

 

 

 

4

STATUS (GREEN) light

Software is initializing your system

 

 

stays off for up to 10 seconds,

configuration.

 

 

then turns green.

 

 

 

 

 

Hardware Failure If the TEST light turns on and remains on, one or more of the diagnostic tests have failed, indicating there is a hardware problem. Contact 3Com for possible repairs to your PathBuilder S21x switch.

Diagnostic Failure If the TEST light does not blink at all, but the Status light is on, the diagnostic software image is corrupted. Perform a download of the software option bundle.

Powerup Failure If the STATUS light blinks continuously, at a constant rate, the software bundle in Flash memory is corrupted. Perform a cold load of the software option bundle. See the Software Installation and Coldloading Manual (Part No. T0028) for more information.