13.3 Biamp System Parameters

Parameter

Unit/Name

Low Section

High Section

 

 

 

 

Gain

(dB)

0

-6

Delay

(ms)

0

0

Polarity

 

Positive

Positive

 

 

 

 

HPF â

Freq (Hz)

45.1

1920

 

Slope (dB/oct)

24

24

 

Filter Shape

Butterworth

Linkwitz Riley

 

 

 

 

LPF

Freq (Hz)

1820

Thru

 

Slope (dB/oct)

24

NA

 

Filter Shape

Linkwitz Riley

NA

 

 

 

 

PEQ 1 â

Freq (Hz)

60.1

6100

 

Level (dB)

+7

+3.5

 

Type

Parametric

Hi - Shelf

 

Q / Bandwidth

2.8 / 0.3536

NA

 

 

 

 

PEQ 2

Freq (Hz)

281

10500

 

Level (dB)

-2.5

+4

 

Type

Parametric

Parametric

 

Q / Bandwidth

2 / 0.500

9.5 / 0.1051

 

 

 

 

PEQ 3

Freq (Hz)

749

NA

 

Level (dB)

-2

NA

 

Type

Parametric

NA

 

Q / Bandwidth

2 / 0.500

NA

 

 

 

 

PEQ 4

Freq (Hz)

606

NA

 

Level (dB)

-2

NA

 

Type

Parametric

NA

 

Q / Bandwidth

6 / 1.669

NA

 

 

 

 

PEQ 5

Freq (Hz)

1650

NA

 

Level (dB)

-2

NA

 

Type

Parametric

NA

 

Q / Bandwidth

7.1 / 0.1403

NA

 

 

 

 

âNote : When using the V300 with subs, set HPF on LF section @ 80 – 100Hz (24dB/oct LR) and omit PEQ1 (on LF only)

PEQ 1 (on LF only) may also be omitted when using the V300 as a floor monitor.