Figure 4-6. Disassembling the drive shaft

E. Blower Belt
1. Remove the eight screws shown in Figure 4-7. Then,
remove the rear panel from the oven.
2. Check the blower belt for the proper 1/4 (6mm) deflec-
tion at the center, and for cracking or excessive wear.
See Figure 4-7. Overtightening the belt will cause premature
bearing failure and possible vibrations. A loose belt may also
cause vibrations.
3. If necessary, adjust the tension of the belt by loosening
the four motor mounting bolts. Reposition the motor as
neccessary until the correct 1/4 (6mm) deflection is
reached, then tighten the bolts.

Figure 4-7. Rear panel access

Remove eight (8)
screws to remove
rear panel
Blower belt
Bearings
(2 total)
Blower motor
Loosen four (4) screws to adjust
motor position and belt tension
IV. MAINTENANCE - EVERY 6 MONTHS
A. Check that the oven is cool and the power is discon-
nected, as described in the warning at the beginning of
this Section.
B. Check for excessive wear on the conveyor drive motor
brushes. The brushes should be replaced if they have
worn to less than

1/4"

(6mm) in length. Be sure to replace
the brushes in exactly the same position.
C. For gas ovens, inspect and clean the burner nozzle and
the spark electrode assembly.
D. Check the conveyor drive shaft bushings and spacers.
Replace the components if they are worn.

25