SystemOperation

Turningyoursystemonandoff

Powerisappliedandremovedwithakeyswitchlocatedontheelectronicsenclosure.Twokeysaresuppliedwiththesystem.
Removethekeywhilethesystemisoperatingtopreventpatronsfromturningoffthesystem.Ifthekeyisnotavailableand
powermustberemoved,unplugthepowercordorturnoffthecircuitbreakerinthepowerdistributionpanelthatsupplies
powertothesystem.Y ourdetectionsystemhasbeendesignedtobeleftoncontinuously.

Turningthesystemon

1.Ensurethatthepowercordisconnectedtoapoweroutletorothersourceofpower.
2.TurnthekeyswitchtotheOnposition.
3.Allow15secondsforthesystemtowarmup.

Turningthesystemoff

Removepowerfromthesystembyoneofthefollowingmethods:
TurnthekeyswitchtotheOffposition.
DisconnecttheACpowercordfromthepoweroutlet.
SetthefacilitycircuitbreakerforthesystemtotheOffposition.

Verifyingsystemoperation

Yoursystemshouldbeinspecteddailyforproperoperation.T overifysystemoperation,walkthroughthesystemcorridor
withasecuredlibraryitem.Thisshouldresultinanaudiblealarmandaflashingalarmlightatthetopofthelattices.Also,
thegreenalarm/inhibitlightontheelectronicsenclosureshouldbeflashingyellowatthetimeofalarm.Thereisnoneed
forrepetitivewalk-throughtesting.Duringnormaloperation,thecurrentpatroncountisdisplayed.Eachpassthrough
thesystemshouldincrementthepatroncounterbyone.

Fusereplacement

Thefusesarelocatedonthebottomoftheelectronicsenclosureinthepowerentryconnector.
1.TurnthekeyswitchtoOffanddisconnectthepowercordfromthepowersource.
2.Usingasmallflat-bladescrewdriver,removethefuseblockfromthepowerentryconnector.
3.Donotremovethevoltageselectionblockasthishasbeensetatthecorrectvoltagebytheinstaller.
4.Replacethefailedfuseswiththecorrectfuseforyouroperatingvoltage:
Upto100to120VAC,usea4Afuse.
Voltagesover220to240VAC,usea3.15Afuse.
5.Reinstallthefuseblock,connectthepowercordtothepowersource,andturnthekeyswitchtoOn.
Copyright©2008.3M.Allrightsreserved.15