3M FSTMO75 manual Troubleshooting Guide, Problem Cause Solution

Models: FSTMO75

1 12
Download 12 pages 7.91 Kb
Page 8
Image 8

Troubleshooting Guide

Problem

Cause

Solution

Notes

 

 

 

 

 

 

Repair Beverage Booster

Contact Dealer

 

 

Pump/System

 

Low Feed Water Pressure

 

 

 

 

 

Add Booster Pump Assembly

Only if Beverage Booster System is

 

 

 

 

not installed

 

 

 

 

 

 

 

 

RO Membrane Fouled

Replace RO Module and SFC

Feed Water Pressure, Temperature,

 

RO Module Flow Rate and Reject

 

Tubing (Stealth Flow Control)

Unit Runs Low or

 

Water should be checked

 

 

Out of Water

 

Drain Tank using Sample Valve,

Unscrew Blue Cap to access Schrader

 

Storage Tank Air Charge

with Sample Valve Open, Pump-

 

up Air Charge, 8 -10 psi (55.2

Air Valve

 

is Low

 

 

- 68.9 kPa), close Sample Valve

 

 

Pre-Filter is Plugged by

Replace Pre-Filter

A more frequent Pre-Filter change-out

 

Sediment (Particles)

schedule may be needed

 

 

 

 

 

 

 

Slow Leak in the Distribu-

 

The unit produces filtered water

 

Repair Leak

slowly. A dripping leak can prevent

 

tion Line

 

the tank from filling

 

 

 

 

 

 

 

 

RO Membrane Partially

Replace RO Module and SFC

High levels of hardness minerals may

 

Fouled, Unit can not pro-

 

be present in feed water, monitor

 

duce enough water to

Tubing (Stealth Flow Control)

 

reject flow for plugging

 

keep up the demand

 

 

 

 

 

 

 

 

Unit Never Shuts Off

 

Check Reject Water flow to drain

 

Product Water Check

in the morning. Unit should be

 

(Continually Runs to

 

off and no flow to drain. If flow

 

Drain)

Valve has failed allowing

Reject Water flow to drain should stop

to drain exists, turn off the feed

 

storage tank flow to drain

when the feed water valve is off

 

water valve and check for flow to

 

after unit is shut off

drain on 10 minutes. If the flow

 

 

 

 

 

 

to drain remains steady, replace

 

 

 

RO Module

 

 

Hydraulic Shut-off Valve

Replace valve

Should only be performed by a quali-

 

has failed

fied technician

 

 

 

 

 

 

8

Page 8
Image 8
3M FSTMO75 manual Troubleshooting Guide, Problem Cause Solution