6M150 FPD Monitor Installation Guide

CAUTION

To avoid the risk of electric shock which may result in minor or moderate injury:

The socket-outlet should be installed near the equipment and should be easily accessible. Use a power cable that is properly grounded. Always use the appropriate AC cord certified for the individual country. Some examples are listed below:

USA

UL

Switzerland

SEV

Canada

CSA

Britain

BASE/BS

Germany

VDE

Japan

Electric Appliance Control Act

Do not service the Flat Panel Display.

There are no user serviceable parts inside.

Refer all servicing to qualified service personnel. The backlight inverter output is at high voltage.

Do not use non-conforming replacement parts. Do not place wet or damp objects on the monitor.

Do not expose the monitor to rain or other sources of water, steam, or moisture. Do not place foreign objects on the monitor or its cables.

Do not remove the cover or back of the monitor.

To avoid the risk of glass breakage which may result in minor or moderate injury: Handle the monitor with care to avoid breaking the touch screen sensor. The display contains glass parts. Dropping the display may cause the glass parts to break.

Do not place foreign objects on the monitor.

To avoid the potentially hazardous situations associated with the use of isopropyl alcohol which may result in minor or moderate injury or property damage:

Follow all instructions and recommendations in the manufacturer's Material Safety Data Sheet and product label.

To avoid possible environmental contamination which may result in minor or moderate injury:

Dispose of the flat panel display according to applicable governmental regulations.

Explanation of Symbols

Attention: Read accompanying documentation

Important Notes:

Plug power cord into appropriate power source.

Plug power cord into a grounded receptacle.

When unplugging power supply cord, pull on plug not cord.

Do not connect or disconnect this product during an electrical storm.

Install the display in a well-ventilated area. Always maintain adequate ventilation to protect the display from overheating and to ensure reliable and continued operation.

Do not expose this display to heat. Passive heat may cause damage to the case and other parts.

Do not install this display in areas where extreme vibrations may be generated. For example, nearby manufacturing equipment may produce strong vibrations. The vibrations may cause the display to exhibit picture discoloration or poor video quality.

Ensure that metal does not contact the touch screen.

3M Touch Systems Proprietary Information

Page 6
Image 6
3M M150 manual Explanation of Symbols, Vde

M150 specifications

The 3M M150 is a groundbreaking device that has redefined the landscape of personal protective equipment in various industrial settings. Known for its exceptional filtration capabilities and comfortable fit, the M150 is at the forefront of respiratory protection technology.

One of the standout features of the 3M M150 is its advanced filtration system, which employs a multi-layer design. This system includes a pre-filter that captures larger particles, allowing the main filter to focus on smaller, harmful contaminants. This two-stage filtration not only enhances the efficiency of the respiratory protection but also extends the lifespan of the filter, making it an economical choice for users.

The M150 utilizes 3M's proprietary Comfort and Convenience Technology, providing users with a snug yet comfortable fit. The lightweight materials used in its construction reduce fatigue even during prolonged wear, which is particularly important for professionals in construction, manufacturing, and healthcare sectors. An adjustable head strap allows for a customizable fit, ensuring that the mask remains securely in place without causing discomfort over extended periods.

Another significant characteristic of the 3M M150 is its compatibility with other personal protective equipment. Designed with versatility in mind, the M150 can be easily paired with safety goggles, face shields, and hearing protection systems. This interoperability is crucial in environments where multiple hazards exist, allowing users to maintain comprehensive safety without compromising comfort.

The M150 features a low-profile design that enhances visibility and minimizes interference with other equipment, making it a practical choice for work in confined spaces or environments requiring detailed visual tasks. Additionally, the quick-release design of the head straps allows for easy removal and replacement, facilitating quick transitions between tasks.

In terms of maintenance, the 3M M150 is designed for easy cleaning and upkeep. The filter elements can be replaced without difficulty, ensuring that users can maintain optimal performance with minimal downtime. Overall, the 3M M150 stands out as a leader in the respiratory protection market, combining cutting-edge technology with user-centric design elements to meet the diverse needs of professionals across various industries. Its commitment to safety, comfort, and efficiency makes it an invaluable tool for those exposed to hazardous environments.