I/O Module Troubleshooting

Symptom Possible Cause Solution
The Standby button on the I/O
module does not light while the
projector is powered on.
The communication cable is not
connected or is damaged.
Connect a communication cable (15
pin to 15 pin) from the projector to
the I/O module.
The projector does not have power. See projector troubleshooting

Projector Troubleshooting

Symptom Standby Button State Possible Cause Action
The projector will not turn
on Off
The power cord is not
connected to projector and
an electrical outlet.
Insert the power cord into
electrical outlet.
The lamp door is not
installed, or is not
properly fastened down.
Make sure the lamp
door is in place and
fastened down as shown
in the lamp replacement
instruction. See page 31.
The projector has
overheated and has
automatically shut down.
Allow the projector cool
down. Once cooled down,
the projector will regain
power and the standby
button will light up. Clean
the projector’s air vents as
mention the maintenance
section.
The electrical outlet does
not have power
Connect the projector to
an electric outlet that has
power. You can the test
the outlet using another
electrical appliance to
confirm that it has power.
The projectors power unit
has stopped working
Contact 3M for service.