4XEM IPCAMWPTZ manual Query Status of the Digital Input

Models: IPCAMWPTZ

1 89
Download 89 pages 41.59 Kb
Page 79
Image 79

NO (normal open) connected with COMMON. The number of DO dependents on the server type.

parameter

Value

description

 

 

 

do<num>

<state>

H – NC connected with COMMON

 

 

L – NO connected with COMMON

 

 

 

return

<return page>

Redirect to the page <return page> after the

 

 

parameter is assigned. The <return page> can be

 

 

a full URL path or relative path according the the

 

 

current path. If you omit this parameter, it will

 

 

redirect to an empty page.

 

 

 

Example: Drive the digital output 1 to high and redirect to an empty page

http://myserver/cgi-bin/setdo.cgi?do1=H

Query Status of the Digital Input

Note: This request requires the privilege of I/O access control.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/getdi.cgi?[di1][&di2][&di3][&di4]

If no parameter is specified, all the status of digital input will be returned.

Return:

HTTP/1.0 200 OK\r\n Content-Type: image/jpeg\r\n Content-Length: <length>\r\n \r\n

[di1=<state>]\r\n [di2=<state>]\r\n [di3=<state>]\r\n [di4=<state>]\r\n

- 75 -