1.3.2Technical data
Device category: II2H3+
DESCRIPTION | unit | EQ 280 | EQ 380 |
DATA NATURAL GAS G20 - 20 mbar:
Nominal heat input (lower value) | kW | 22.6 | 24.0 |
Nominal power | kW | 19.2 | 20.4 |
mbar | 20 | 20 | |
Burner pressure (G20) | mbar | 12.5 | 8.7 |
Gas consumption (G20) * | m3/h | 2.4 | 2.5 |
Diameter main orifice (G20) | mm | 3.90 | 4.50 |
Diameter pilot orifice (G20) | mm | 2 X 0,27 | 2 X 0,27 |
min. | 56 | 61 | |
DATA BUTANE G30 - 30 mbar: |
|
|
|
Nominal heat input (lower value) | kW | 22.6 | 24.0 |
Nominal power | kW | - | - |
mbar | 30 | 30 | |
Burner pressure (G30) | mbar | 30 | 30 |
Gas consumption (G30) * | kg/h | 1.8 | 1.9 |
Diameter main orifice (G30) | mm | 2.30 | 2.35 |
Diameter pilot orifice (G30) | mm | 2 x 0.16 | 2 x 0.16 |
min. | - | - | |
DATA PROPANE G31 - 37 mbar |
|
|
|
Nominal heat input (lower value) | kW | 21.1 | 22.9 |
Nominal power | kW | - | - |
mbar | 37 | 37 | |
Burner pressure (G31) | mbar | 37 | 37 |
Gas consumption (G31) * | kg/h | 1.6 | 1.8 |
Diameter main orifice (G31) | mm | 2.25 | 2.35 |
Diameter pilot orifice (G31) | mm | 2 x 0.16 | 2 x 0.16 |
min. | - | - |