A.O. Smith EQ 380 G, EQ 280 G manual Technical data, Device category II2H3+

Models: EQ 280 G EQ 380 G

1 28
Download 28 pages 47 Kb
Page 10
Image 10

1.3.2Technical data

Device category: II2H3+

DESCRIPTION

unit

EQ 280

EQ 380

DATA NATURAL GAS G20 - 20 mbar:

Nominal heat input (lower value)

kW

22.6

24.0

Nominal power

kW

19.2

20.4

Inlet-pressure (G20)

mbar

20

20

Burner pressure (G20)

mbar

12.5

8.7

Gas consumption (G20) *

m3/h

2.4

2.5

Diameter main orifice (G20)

mm

3.90

4.50

Diameter pilot orifice (G20)

mm

2 X 0,27

2 X 0,27

Warming-up time ΔT= 45 K

min.

56

61

DATA BUTANE G30 - 30 mbar:

 

 

 

Nominal heat input (lower value)

kW

22.6

24.0

Nominal power

kW

-

-

Inlet-pressure (G30)

mbar

30

30

Burner pressure (G30)

mbar

30

30

Gas consumption (G30) *

kg/h

1.8

1.9

Diameter main orifice (G30)

mm

2.30

2.35

Diameter pilot orifice (G30)

mm

2 x 0.16

2 x 0.16

Warming-up time ΔT= 45 K

min.

-

-

DATA PROPANE G31 - 37 mbar

 

 

 

Nominal heat input (lower value)

kW

21.1

22.9

Nominal power

kW

-

-

Inlet-pressure (G31)

mbar

37

37

Burner pressure (G31)

mbar

37

37

Gas consumption (G31) *

kg/h

1.6

1.8

Diameter main orifice (G31)

mm

2.25

2.35

Diameter pilot orifice (G31)

mm

2 x 0.16

2 x 0.16

Warming-up time ΔT= 45 K

min.

-

-

10

Page 10
Image 10
A.O. Smith EQ 380 G, EQ 280 G manual Technical data, Device category II2H3+