4 screws used to temporarily attach the collar to the exterior wall. Then secure the vent cap assembly with the vent collar assembly to the exterior wall using the same 4 screws.

NOTE: Screws are supplied; however, substitution may be necessary depending on the exterior wall material.

FIGURE 91

19.Move indoors to complete the assembly process.

20.Collapse the 6” vent extension pipes as shown below and install the 3” extension by first slipping the end with the O-ring approximately 1 1/4” into the end of the vent cap. Lock the other end of the 3” extension assembly to the studs in the elbow.

FIGURE 92

NOTE: To facilitate ease of assembly of the vent cap to the 3” pipe, a soap solution can be applied to the O-ring gasket.

FIGURE 93

21.Using a #22 drill bit, drill holes 180° apart at the connection point of the two 3” flue extensions. Then using 2 screws provided, lock these pipes together.

FIGURE 94

22.Now the 6” vent extension pipes can be expanded to connect at the vent elbow.

FIGURE 95

23.Pull the vent collar from the elbow to be against the wall and secure it using the screws provided.

FIGURE 96

24.Lock the 6” vent extension to the vent elbow by using two screws provided, placing them 180° apart.

FIGURE 97

OPERATION

NEVER OPERATE THE HEATER WITHOUT FIRST BEING CERTAIN IT IS FILLED WITH WATER AND A TEMPERATURE AND PRESSURE RELIEF VALVE IS INSTALLED IN THE RELIEF VALVE OPENING OF THE HEATER. DO NOT ATTEMPT TO OPERATE HEATER WITH COLD WATER INLET VALVE CLOSED.

FILLING

1.Close the heater drain valve (Fig. 1) by turning handle clockwise.

2.Open a nearby hot water faucet to permit the air in the system to escape.

3.Fully open the cold water inlet pipe valve (Fig. 1) allowing the heater and piping to be filled.

4.Close the hot water faucet as water starts to flow.

5.The heater is ready to be operated.

HIGH ALTITUDE INSTALLATIONS

WARNING

INSTALLATIONS ABOVE 2,000 FT. REQUIRE REPLACEMENT OF THE BURNER ORIFICE IN ACCORDANCE WITH THE NATIONAL FUEL GAS CODE (ANSI Z223.1/NFPA 54). FAILURE TO REPLACE THE ORIFICE COULD RESULT IN IMPROPER AND INEFFICIENT OPERATION OF THE APPLIANCE, PRODUCING CARBON MONOXIDE GAS IN EXCESS OF SAFE LIMITS, WHICH COULD RESULT IN SERIOUS PERSONAL INJURY OR DEATH. CONTACT YOUR GAS SUPPLY FOR ANY SPECIFIC CHANGES WHICH MAY BE REQUIRED IN YOUR AREA.

A. O. Smith builds models specifically for high altitude service. Please check the rating plate before making changes.

18

Page 18
Image 18
A.O. Smith FDVT, SDV owner manual Operation, Filling, High Altitude Installations

SDV, FDVT, FDV specifications

A.O. Smith is a leading name in the water heating industry, known for its innovative products and commitment to quality. Among its extensive lineup, the FDV, FDVT, and SDV series stand out due to their advanced features and technologies designed to enhance performance and efficiency.

The FDV series represents a revolution in traditional water heating solutions. These direct vent water heaters are designed to provide hot water on demand while minimizing energy consumption. The FDV models utilize a dual venting system, allowing for the efficient expulsion of combustion gases outside the home while drawing in fresh air for the combustion process. This design increases efficiency by ensuring optimal combustion and improves safety by reducing the risk of indoor air contamination.

The FDVT series builds upon the innovative features of the FDV, integrating a tankless design that provides unlimited hot water. This makes it an ideal choice for households with higher hot water demands. The FDVT models use high-efficiency burners and advanced heat exchangers to deliver hot water quickly and consistently, adapting to varying flow rates. They are also equipped with intelligent control systems that monitor water usage patterns and adjust operation accordingly, optimizing energy efficiency without sacrificing performance.

The SDV series caters to those looking for a reliable and efficient storage tank water heater. With a robust construction and reliable design, these water heaters are built to last. The SDV models are designed with high-quality insulation to minimize heat loss, making them energy-efficient options for storing hot water. Additional features include built-in safety mechanisms, such as temperature and pressure relief valves, ensuring safe operation at all times.

A.O. Smith's commitment to innovation is evident in their use of cutting-edge technologies across these series. Both the FDV and FDVT models incorporate sophisticated electronic controls, enabling features like scheduling and remote access for greater convenience. They are compatible with smart home systems, allowing users to monitor and manage water heating remotely.

In terms of energy efficiency, models within these series are designed to exceed industry standards, often qualifying for energy rebates and incentives in various regions. With features such as modulating burners, they adjust the energy input based on demand, significantly reducing operational costs.

Overall, A.O. Smith's FDV, FDVT, and SDV series represent leading-edge solutions in water heating, combining efficiency, safety, and advanced technology to meet the diverse needs of modern households. Whether seeking endless hot water or reliable storage solutions, these series offer unparalleled options that prioritize performance and sustainability.