SEDIMENT TRAPS

 

FILLING THE WATER HEATER

A drip leg (sediment trap) shall be installed as close to the inlet of the water heater as practical at the time of water heater installa- tion. The sediment trap shall be either a tee fitting with a capped nipple in the bottom outlet or other device recognized as an ef- fective sediment trap. If a tee fitting is used, it shall be installed in conformance with one of the methods of installation shown in Figures 8 and 9.

Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion. Before attaching the gas line be sure that all gas pipe is clean on the inside. To trap any dirt or foreign material in the gas supply line, a drip leg (sometimes called a sediment trap) must be incor- porated in the piping. The drip leg must be readily accessible. Install in accordance with the “Gas Piping” section. Refer to the current edition of the “Natural Gas and Propane Installation Code” CAN/CSA-B149.1

HOT WATER

COLD WATER

OUTLET

INTLET

UNION

SHUTOFF

VALVE

 

 

UNION

 

TEMPERATURE

 

AND PRESSURE

 

RELIEF VALVE

DISCHARGE PIPE (DO NOT CAP OR PLUG)

 

DRAIN PAN

DRAIN VALVE

6” MAXIMUM

 

AIR GAP

FLOOR DRAIN

 

FIGURE 10

Never use this water heater unless it is completely full of water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning “ON” gas to the water heater.

To fill the water heater with water:

1.Close the water heater drain valve by turning the handle clockwise (). The drain valve is on the lower front of the water heater.

2.Open the cold water supply valve to the water heater. NOTE: The cold water supply valve must be left open when the water heater is in use.

3.To insure complete filling of the tank, allow air to exit by open- ing the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the water heater and the piping.

4.Check all water piping and connections for leaks. Repair as needed.

VENTING

NEVER OPERATE THE HEATER UNLESS IT IS VENTED TO THE OUTDOORS AND HAS ADEQUATE AIR SUPPLY TO AVOID RISKS OF IMPROPER OPERATION, FIRE, EXPLOSION OR ASPHYXIATION.

DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATING AIR. ADEQUATE AIR FOR COMBUSTION AND VENTILATION MUST BE PROVIDED FOR SAFE OPERATION.

HIGH ALTITUDE INSTALLATIONS

Installations above 7,700 ft. (2347 m) require replacement of the burner orifice in accordance with the “Natural Gas and Pro- pane Installation Code” CAN/CSA-B149.1. Failure to replace the orifice could result in improper and inefficient operation of the appliance, producing carbon monoxide gas in excess of safe limits, which could result in serious personal injury or death. Contact your gas supplier for any specific changes which may be required in your area.

13

Page 13
Image 13
A.O. Smith GDV-40, GDVT-50, GDV-50, GDV-75 Sediment Traps Filling the Water Heater, Venting, High Altitude Installations

186589-004, GDVT-50, GDV-75, GDV-40, GDV-50 specifications

A.O. Smith is a recognized name in the water heating industry, known for its reliable and efficient water heaters. Among its notable products are the GDV-50, GDV-40, GDV-75, GDVT-50, and 186589-004 models. These water heaters offer enhanced performance, energy efficiency, and modern technologies suited for residential and commercial applications.

The GDV series includes the GDV-50, GDV-40, and GDV-75 models, which feature a robust design typically made from high-quality materials to ensure longevity. These units come equipped with advanced insulation, which minimizes heat loss and increases efficiency, making them excellent choices for households with varying hot water needs.

The GDV-50 model boasts a tank capacity of 50 gallons, making it suitable for medium to large households. It features a powerful heating element that heats water quickly, providing ample hot water for daily use. Meanwhile, the GDV-40 is designed for smaller households with a 40-gallon capacity. This model strikes a balance between size and efficiency, catering to lighter hot water demands while maintaining excellent performance.

For larger households, the GDV-75 provides a 75-gallon capacity, ensuring that even the most demanding hot water applications can be met with ease. This model is particularly ideal for families that require hot water in large quantities or at peak times.

The GDVT-50 is a versatile model that features advanced technology, such as an integrated digital display that allows users to monitor and adjust settings easily. This offers greater control over temperature settings and energy usage, making it not only convenient but also more energy-efficient.

The A.O. Smith 186589-004 is an accessory designed for specific model enhancements that improve overall performance and safety. It may include additional safety features, such as high-temperature limit switches and automatic shut-off mechanisms that provide peace of mind for users.

All these models are equipped with A.O. Smith’s innovative technologies, including advanced thermostat controls and durable components designed to withstand frequent use. They typically come with generous warranties, underscoring the manufacturer's commitment to quality and customer satisfaction.

In summary, A.O. Smith water heaters, particularly the GDV-50, GDV-40, GDV-75, GDVT-50, and 186589-004, are built for efficiency, reliability, and performance. With various capacities and the latest technologies, they cater to the diverse needs of homeowners and businesses, ensuring that hot water is always available when needed.