INSULATION BLANKETS

Insulation blankets available to the general public for external use on gas water heaters are not necessary with this product. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank water heaters. Your Water heater meets or exceeds the National Appliance Energy Conser- vation Act standards with respect to insulation and standby loss requirements, making an insulation blanket unnecessary.

Should you choose to apply an insulation blanket to this heater, you should follow these instructions (See Figure 1 for identifica- tion of components mentioned below). Failure to follow these instructions can restrict the air flow required for proper combus- tion, resulting in fire, asphyxiation, serious personal injury or death.

Do not cover the outer door, thermostat or temperature & pressure relief valve.

Do not cover the instruction manual. Keep it on the side of the water heater or nearby for future reference.

VENTILATION FOR APPLIANCES LOCATED IN CONFINED SPACES

FIGURE 3

Confined Space is a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 cm per kW) of the aggregate input rating of all appliances installed in that space.

VENT TERMINATION

Before installing water heater determine placement of vent ter- mination.

Make certain to observe vent location limitation, see Figures 3, 4 & 12.

Minimum clearances between the water heater and combustible and noncombustible construction are: 0mm (0 in.) from sides, 0mm (0 in.) from back, 102mm (4 in.) from front of jacket to closet door and 508mm (20 in.) from top of jacket to combustible and noncombustible material. Minimum vent clearance: 25mm (1 in.)*. Provide 915mm (3 ft.) front clearance for servicing and adequate clearance between the jacket top & ceiling for servicing the flue area, see Figure 4.

*Where the wall is combustible and the wall thickness is over 356mm (14 in.), 25mm (1 in.) clearance to combustible materials around the vent terminal is needed. The first 356mm (14 in.) is zero clearance.

Make certain the vent locations comply with the “Natural Gas and Propane Installation Code” CAN/CSA-B149.1 and/or lo- cal codes. There is some important information shown in Figure 12.

For a second or more direct vent unit, the distance between vent terminals must be a minimum of 305mm (12 in.).

FIGURE 4

8

Page 8
Image 8
A.O. Smith GDV-40, GDVT-50 Insulation Blankets, Ventilation for Appliances Located in Confined Spaces, Vent Termination

186589-004, GDVT-50, GDV-75, GDV-40, GDV-50 specifications

A.O. Smith is a recognized name in the water heating industry, known for its reliable and efficient water heaters. Among its notable products are the GDV-50, GDV-40, GDV-75, GDVT-50, and 186589-004 models. These water heaters offer enhanced performance, energy efficiency, and modern technologies suited for residential and commercial applications.

The GDV series includes the GDV-50, GDV-40, and GDV-75 models, which feature a robust design typically made from high-quality materials to ensure longevity. These units come equipped with advanced insulation, which minimizes heat loss and increases efficiency, making them excellent choices for households with varying hot water needs.

The GDV-50 model boasts a tank capacity of 50 gallons, making it suitable for medium to large households. It features a powerful heating element that heats water quickly, providing ample hot water for daily use. Meanwhile, the GDV-40 is designed for smaller households with a 40-gallon capacity. This model strikes a balance between size and efficiency, catering to lighter hot water demands while maintaining excellent performance.

For larger households, the GDV-75 provides a 75-gallon capacity, ensuring that even the most demanding hot water applications can be met with ease. This model is particularly ideal for families that require hot water in large quantities or at peak times.

The GDVT-50 is a versatile model that features advanced technology, such as an integrated digital display that allows users to monitor and adjust settings easily. This offers greater control over temperature settings and energy usage, making it not only convenient but also more energy-efficient.

The A.O. Smith 186589-004 is an accessory designed for specific model enhancements that improve overall performance and safety. It may include additional safety features, such as high-temperature limit switches and automatic shut-off mechanisms that provide peace of mind for users.

All these models are equipped with A.O. Smith’s innovative technologies, including advanced thermostat controls and durable components designed to withstand frequent use. They typically come with generous warranties, underscoring the manufacturer's commitment to quality and customer satisfaction.

In summary, A.O. Smith water heaters, particularly the GDV-50, GDV-40, GDV-75, GDVT-50, and 186589-004, are built for efficiency, reliability, and performance. With various capacities and the latest technologies, they cater to the diverse needs of homeowners and businesses, ensuring that hot water is always available when needed.