312A

CHIMNEY INSPECTION CHART

For additional requirements refer to the National Fuel Gas Code NFPA 54/ANSI Z223.1 and ANSI/NFPA 211

Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances in the U.S.A. or to the Canadian

installation Code CSA-B149.1 in Canada.

Crown

 

Rebuild

condition:

Yes

Missing mortar

 

crown.

 

or brick?

 

 

No

 

 

 

 

 

 

 

 

Is chimney

 

No

 

 

 

 

 

 

property lined with

 

 

 

 

 

 

 

 

 

 

 

 

 

clay tile liner?

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

Is

 

No

 

Repair

Reline

 

 

 

liner and top

 

 

liner or top seal

 

 

 

seal in good

 

 

or reline chimney as

 

 

 

 

condition?

 

 

 

necessary.

 

 

 

 

Yes

 

 

 

Repair

 

 

 

 

Debris

 

 

 

Mortar

 

 

 

 

in cleanout?

 

Yes

 

Yes

Remove mortar

 

Mortar, tile, metal vent,

 

 

or tile

 

and tile debris

 

fuel oil residue?

 

 

debris?

 

 

 

 

 

 

 

 

No

Remove metal vent

No

 

 

 

 

 

 

or liner.

 

 

 

 

 

 

 

 

 

 

 

 

 

Clay

 

Yes

 

 

 

 

 

 

tile misalignment,

 

 

 

 

 

 

missing sections,

 

 

 

 

 

 

 

gaps?

 

 

 

 

Consult

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Part B of

 

Not Suitable

 

No

 

 

 

chimney adapter venting

 

 

 

 

 

 

 

 

 

 

 

No

instructions for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

application

 

 

 

 

 

 

 

Is chimney

suitability.

 

 

 

Condensate

 

 

 

 

 

 

Line chimney with property

 

 

lined with properly

Suitable

 

 

 

 

 

 

sized, listed flexible metal

drainage at bottom

 

sized, listed liner or

 

 

 

of chimney?

 

 

Yes

 

 

liner or Type-B vent per

 

 

Type-B vent?

 

 

 

Yes

 

 

 

 

NFGC or NSCNGPIC Vent

 

 

 

 

Install chimney

Sizing Tables and liner or

 

 

 

 

 

vent manufacturer’s

No

 

 

 

 

adapter per

 

 

 

 

 

 

Installation instructions.

 

 

 

 

instructions.

Not Suitable

 

 

 

 

Yes

 

 

 

 

 

 

 

 

Chimney

 

 

 

Consult

 

 

Is chimney

No

Part C of

 

exposed to

 

Suitable

 

to be dedicated to

 

chimney adapter venting

outdoors below

 

a single

 

instructions for

 

roof line?

Yes

furnace?

 

application

 

 

 

 

 

suitability

 

No

 

 

 

 

Install chimney

 

 

 

 

 

adapter per

 

 

 

 

 

instructions.

Chimney is

 

 

 

 

 

acceptable for use.

 

 

 

 

 

A03206

Fig. 35 - Chimney Inspection Chart

28

Page 28
Image 28
Bryant 120 instruction manual Chimney Inspection Chart

120 specifications

The Bryant 120 is a remarkable system designed for residential and commercial heating and cooling needs, showcasing an impressive blend of efficiency, reliability, and advanced technology. As a part of Bryant's extensive line of HVAC solutions, the Bryant 120 stands out with its features and performance, making it an ideal choice for those seeking comfort year-round.

One of the main features of the Bryant 120 is its exceptional energy efficiency. It boasts a high Seasonal Energy Efficiency Ratio (SEER) rating, enabling homeowners to save on energy costs while enjoying consistent temperature control. This efficiency is aided by its variable-speed compressor, which allows the system to adjust its output based on current requirements, optimizing both energy consumption and comfort.

In terms of technology, the Bryant 120 incorporates advanced controls that enhance user experience and system performance. The system comes equipped with smart thermostats that allow homeowners to monitor and adjust their environment remotely. These thermostats not only provide convenience but also help in optimizing energy usage by learning the household's heating and cooling patterns.

Another characteristic of the Bryant 120 is its durable construction. The unit is built to withstand various weather conditions, featuring a robust cabinet and components designed for longevity. This durability ensures that homeowners can rely on the system for years without the need for frequent repairs or replacements.

Noise levels are also a critical consideration in HVAC systems, and the Bryant 120 addresses this with its quiet operation. The system is designed to minimize sound output, making it suitable for residential areas where noise can be a concern. This is particularly beneficial for nighttime use, providing a comfortable sleeping environment.

Additionally, the Bryant 120 supports eco-friendly refrigerants that comply with environmental standards, contributing to a reduction in greenhouse gas emissions. This commitment to sustainability reflects Bryant's dedication to creating products that are not only effective but also responsible.

Overall, the Bryant 120 encapsulates a harmonious balance of efficiency, advanced technology, durability, and quiet operation. Whether for a new installation or a replacement, the Bryant 120 presents an ideal solution to meet diverse heating and cooling requirements, enhancing comfort while prioritizing energy savings and environmental responsibility.