312A

Table 16 – Orifice Size and Manifold Pressure for Gas Input Rate

(Tabulated Data Based on 21,000 Btuh High-Heat/14,500 Btuh for Low-Heat Per Burner, Derated 4% for Each 1000 Ft Above Sea

level)

 

 

 

AVG. GAS

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

ALTITUDE RANGE

 

0.58

 

0.60

 

0.62

 

0.64

HEAT VALUE

 

 

 

 

 

(FT)

 

 

 

 

 

 

 

 

 

 

 

 

 

(BTUH/CU FT)

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

 

 

 

 

 

 

 

 

900

42

 

3.2/1.5

42

 

3.3/1.6

42

 

3.4/1.6

42

 

3.5/1.7

 

 

 

925

43

 

3.7/1.8

43

 

3.8/1.8

42

 

3.2/1.5

42

 

3.3/1.6

 

 

 

950

43

 

3.5/1.7

43

 

3.6/1.7

43

 

3.7/1.8

43

 

3.8/1.8

U.S.A.

 

0 to

975

43

 

3.3/1.6

43

 

3.4/1.6

43

 

3.5/1.7

43

 

3.7/1.7

and

 

1000

44

 

3.6/1.7

43

 

3.3/1.6

43

 

3.4/1.6

43

 

3.5/1.7

 

2000

 

 

 

 

Canada

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1025

44

 

3.4/1.6

44

 

3.6/1.7

43

 

3.2/1.5

43

 

3.3/1.6

 

 

 

 

 

 

 

 

 

1050

44

 

3.3/1.6

44

 

3.4/1.6

44

 

3.5/1.7

43

 

3.2/1.5

 

 

 

1075

45

 

3.8/1.8

44

 

3.2/1.5

44

 

3.3/1.6

44

 

3.4/1.6

 

 

 

1100

46

 

3.8/1.8

45

 

3.7/1.8

44

 

3.2/1.5

44

 

3.3/1.6

 

 

 

AVG. GAS

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

ALTITUDE RANGE

 

0.58

 

0.60

 

0.62

 

0.64

HEAT VALUE

 

 

 

 

 

(FT)

 

 

 

 

 

 

 

 

 

 

 

 

 

(BTUH/CU FT)

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

 

 

 

 

 

 

 

U.S.A.

800

43

 

3.8/1.8

42

 

3.2/1.5

42

 

3.3/1.6

42

 

3.4/1.6

 

 

825

43

 

3.5/1.7

43

 

3.7/1.7

43

 

3.8/1.8

42

 

3.2/1.5

 

 

Altitudes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

850

43

 

3.3/1.6

43

 

3.5/1.6

43

 

3.6/1.7

43

 

3.7/1.8

 

 

2001 to

 

 

 

 

 

 

 

 

 

 

 

 

 

U.S.A.

 

875

43

 

3.2/1.5

43

 

3.3/1.6

43

 

3.4/1.6

43

 

3.5/1.7

 

3000 or

 

 

 

 

and

 

900

44

 

3.4/1.6

44

 

3.5/1.7

43

 

3.2/1.5

43

 

3.3/1.6

 

Canada

 

 

 

 

Canada

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

925

44

 

3.2/1.5

44

 

3.3/1.6

44

 

3.5/1.6

44

 

3.6/1.7

 

Altitudes

 

 

 

 

 

 

2001 to

950

45

 

3.7/1.8

45

 

3.8/1.8

44

 

3.3/1.6

44

 

3.4/1.6

 

 

4500

975

46

 

3.7/1.8

46

 

3.8/1.8

45

 

3.8/1.8

44

 

3.2/1.5

 

 

 

1000

46

 

3.5/1.7

46

 

3.6/1.7

46

 

3.8/1.8

45

 

3.7/1.8

 

 

 

AVG. GAS

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

ALTITUDE RANGE

 

0.58

 

0.60

 

0.62

 

0.64

HEAT VALUE

 

 

 

 

 

(FT)

(BTUH/CU FT)

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

 

 

 

 

 

 

 

 

775

43

 

3.5/1.7

43

 

3.7/1.7

43

 

3.8/1.8

42

 

3.2/1.5

 

 

 

800

43

 

3.3/1.6

43

 

3.4/1.6

43

 

3.5/1.7

43

 

3.7/1.7

 

 

 

825

44

 

3.6/1.7

43

 

3.2/1.5

43

 

3.3/1.6

43

 

3.4/1.6

U.S.A.

 

3001 to

850

44

 

3.4/1.6

44

 

3.5/1.7

44

 

3.6/1.7

43

 

3.2/1.5

Only

 

4000

875

45

 

3.8/1.8

44

 

3.3/1.6

44

 

3.4/1.6

44

 

3.5/1.7

 

 

 

900

46

 

3.8/1.8

45

 

3.8/1.8

44

 

3.2/1.5

44

 

3.3/1.6

 

 

 

925

46

 

3.6/1.7

46

 

3.7/1.8

45

 

3.7/1.8

45

 

3.8/1.8

 

 

 

950

46

 

3.4/1.6

46

 

3.5/1.7

46

 

3.7/1.7

46

 

3.8/1.8

 

 

 

AVG. GAS

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

ALTITUDE RANGE

 

0.58

 

0.60

 

0.62

 

0.64

HEAT VALUE

 

 

 

 

 

(FT)

 

 

 

 

 

 

 

 

 

 

 

 

 

(BTUH/CU FT)

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

 

 

 

 

 

 

 

 

750

43

 

3.3/1.6

43

 

3.4/1.6

43

 

3.5/1.7

43

 

3.6/1.7

 

 

 

775

44

 

3.6/1.7

43

 

3.2/1.5

43

 

3.3/1.6

43

 

3.4/1.6

 

 

 

800

44

 

3.3/1.6

44

 

3.4/1.6

44

 

3.6/1.7

43

 

3.2/1.5

U.S.A.

 

4001 to

825

45

 

3.8/1.8

44

 

3.2/1.5

44

 

3.4/1.6

44

 

3.5/1.6

Only

 

5000

850

46

 

3.8/1.8

45

 

3.7/1.8

45

 

3.8/1.8

44

 

3.3/1.6

 

 

 

875

46

 

3.5/1.7

46

 

3.7/1.7

46

 

3.8/1.8

45

 

3.7/1.8

 

 

 

900

47

 

3.8/1.8

46

 

3.5/1.7

46

 

3.6/1.7

46

 

3.7/1.8

 

 

 

925

47

 

3.6/1.7

47

 

3.7/1.8

47

 

3.8/1.8

46

 

3.5/1.7

 

 

 

AVG. GAS

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

ALTITUDE RANGE

HEAT VALUE

 

0.58

 

0.60

 

0.62

 

0.64

 

(FT)

AT ALTITUDE

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

 

(BTUH/CU FT)

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

725

44

3.5/1.7

43

3.2/1.5

43

3.3/1.6

43

3.4/1.6

 

 

 

750

44

3.3/1.6

44

3.4/1.6

44

3.5/1.7

43

3.2/1.5

 

 

 

775

45

3.7/1.8

44

3.2/1.5

44

3.3/1.6

44

3.4/1.6

U.S.A.

 

5001 to

800

46

3.7/1.8

46

3.8/1.8

45

3.8/1.8

44

3.2/1.5

Only

6000

825

46

3.5/1.7

46

3.6/1.7

46

3.7/1.8

46

3.8/1.8

 

 

 

850

47

3.7/1.8

47

3.8/1.8

46

3.5/1.7

46

3.6/1.7

 

 

 

875

47

3.5/1.7

47

3.6/1.7

47

3.7/1.8

46

3.4/1.6

 

 

 

900

48

3.8/1.8

47

3.4/1.6

47

3.5/1.7

47

3.7/1.7

* Orifice numbers 43 are factory installed

44

Page 44
Image 44
Bryant 120 instruction manual Specific Gravity of Natural GAS Altitude Range, Btuh/Cu Ft

120 specifications

The Bryant 120 is a remarkable system designed for residential and commercial heating and cooling needs, showcasing an impressive blend of efficiency, reliability, and advanced technology. As a part of Bryant's extensive line of HVAC solutions, the Bryant 120 stands out with its features and performance, making it an ideal choice for those seeking comfort year-round.

One of the main features of the Bryant 120 is its exceptional energy efficiency. It boasts a high Seasonal Energy Efficiency Ratio (SEER) rating, enabling homeowners to save on energy costs while enjoying consistent temperature control. This efficiency is aided by its variable-speed compressor, which allows the system to adjust its output based on current requirements, optimizing both energy consumption and comfort.

In terms of technology, the Bryant 120 incorporates advanced controls that enhance user experience and system performance. The system comes equipped with smart thermostats that allow homeowners to monitor and adjust their environment remotely. These thermostats not only provide convenience but also help in optimizing energy usage by learning the household's heating and cooling patterns.

Another characteristic of the Bryant 120 is its durable construction. The unit is built to withstand various weather conditions, featuring a robust cabinet and components designed for longevity. This durability ensures that homeowners can rely on the system for years without the need for frequent repairs or replacements.

Noise levels are also a critical consideration in HVAC systems, and the Bryant 120 addresses this with its quiet operation. The system is designed to minimize sound output, making it suitable for residential areas where noise can be a concern. This is particularly beneficial for nighttime use, providing a comfortable sleeping environment.

Additionally, the Bryant 120 supports eco-friendly refrigerants that comply with environmental standards, contributing to a reduction in greenhouse gas emissions. This commitment to sustainability reflects Bryant's dedication to creating products that are not only effective but also responsible.

Overall, the Bryant 120 encapsulates a harmonious balance of efficiency, advanced technology, durability, and quiet operation. Whether for a new installation or a replacement, the Bryant 120 presents an ideal solution to meet diverse heating and cooling requirements, enhancing comfort while prioritizing energy savings and environmental responsibility.