Table 16 - Orifice Size and Manifold Pressure for Gas Input Rate (cont.)
(Tabulated Data Based on 21,000 Btuh
Sea level)
|
|
| AVG. GAS |
|
|
| SPECIFIC GRAVITY OF NATURAL GAS |
|
|
| |||||
ALTITUDE RANGE | HEAT VALUE |
| 0.58 |
| 0.60 |
| 0.62 |
| 0.64 | ||||||
| (FT) | AT ALTITUDE |
|
|
|
|
|
|
|
|
|
|
|
| |
| Orifice |
| Manifold | Orifice |
| Manifold | Orifice |
| Manifold | Orifice |
| Manifold | |||
|
|
| (BTUH/CU FT) | No. |
| Pressure | No. |
| Pressure | No. |
| Pressure | No. |
| Pressure |
|
|
| 675 | 44 |
| 3.5/1.7 | 43 |
| 3.2/1.5 | 43 |
| 3.3/1.6 | 43 |
| 3.4/1.6 |
|
|
| 700 | 44 |
| 3.3/1.6 | 44 |
| 3.4/1.6 | 44 |
| 3.5/1.7 | 43 |
| 3.2/1.5 |
|
|
| 725 | 45 |
| 3.7/1.8 | 45 |
| 3.8/1.8 | 44 |
| 3.3/1.6 | 44 |
| 3.4/1.6 |
U.S.A. |
| 6001 to | 750 | 46 |
| 3.6/1.7 | 46 |
| 3.8/1.8 | 45 |
| 3.7/1.8 | 45 |
| 3.8/1.8 |
Only |
| 7000 | 775 | 46 |
| 3.4/1.6 | 46 |
| 3.5/1.7 | 46 |
| 3.6/1.7 | 46 |
| 3.8/1.8 |
|
|
| 800 | 47 |
| 3.6/1.7 | 47 |
| 3.8/1.8 | 46 |
| 3.4/1.6 | 46 |
| 3.5/1.7 |
|
|
| 825 | 47 |
| 3.4/1.6 | 47 |
| 3.5/1.7 | 47 |
| 3.6/1.7 | 47 |
| 3.8/1.8 |
|
|
| 850 | 48 |
| 3.7/1.7 | 48 |
| 3.8/1.8 | 47 |
| 3.4/1.6 | 47 |
| 3.5/1.7 |
|
|
| AVG. GAS |
|
|
| SPECIFIC GRAVITY OF NATURAL GAS |
|
|
| |||||
ALTITUDE RANGE |
| 0.58 |
| 0.60 |
| 0.62 |
| 0.64 | |||||||
HEAT VALUE |
|
|
|
| |||||||||||
| (FT) |
|
|
|
|
|
|
|
|
|
|
|
| ||
| AT ALTITUDE ) | Orifice |
| Manifold | Orifice |
| Manifold | Orifice |
| Manifold | Orifice |
| Manifold | ||
|
|
| No. |
| Pressure | No. |
| Pressure | No. |
| Pressure | No. |
| Pressure | |
|
|
|
|
|
|
|
| ||||||||
|
|
| 650 | 44 |
| 3.3/1.6 | 44 |
| 3.4/1.6 | 44 |
| 3.5/1.7 | 43 |
| 3.2/1.5 |
|
|
| 675 | 45 |
| 3.7/1.8 | 45 |
| 3.8/1.8 | 44 |
| 3.3/1.6 | 44 |
| 3.4/1.6 |
|
|
| 700 | 46 |
| 3.6/1.7 | 46 |
| 3.7/1.8 | 46 |
| 3.8/1.8 | 45 |
| 3.8/1.8 |
U.S.A. |
| 7001 to | 725 | 47 |
| 3.8/1.8 | 46 |
| 3.5/1.7 | 46 |
| 3.6/1.7 | 46 |
| 3.7/1.8 |
Only |
| 8000 | 750 | 47 |
| 3.5/1.7 | 47 |
| 3.7/1.8 | 47 |
| 3.8/1.8 | 46 |
| 3.5/1.6 |
|
|
| 775 | 48 |
| 3.8/1.8 | 47 |
| 3.4/1.6 | 47 |
| 3.6/1.7 | 47 |
| 3.7/1.7 |
|
|
| 800 | 48 |
| 3.6/1.7 | 48 |
| 3.7/1.8 | 48 |
| 3.8/1.8 | 47 |
| 3.4/1.6 |
|
|
| 825 | 48 |
| 3.3/1.6 | 48 |
| 3.5/1.6 | 48 |
| 3.6/1.7 | 48 |
| 3.7/1.8 |
|
|
|
|
|
|
| SPECIFIC GRAVITY OF NATURAL GAS |
|
|
| |||||
ALTITUDE RANGE |
|
| 0.58 |
| 0.60 |
| 0.62 |
| 0.64 | ||||||
| (FT) |
| Orifice |
| Manifold | Orifice |
| Manifold | Orifice |
| Manifold | Orifice |
| Manifold | |
|
|
|
| No. |
| Pressure | No. |
| Pressure | No. |
| Pressure | No. |
| Pressure |
|
|
| 625 | 45 |
| 3.7/1.8 | 45 |
| 3.8/1.8 | 44 |
| 3.3/1.6 | 44 |
| 3.4/1.6 |
|
|
| 650 | 46 |
| 3.6/1.7 | 46 |
| 3.7/1.8 | 46 |
| 3.8/1.8 | 45 |
| 3.8/1.8 |
U.S.A. |
| 8001 to | 675 | 47 |
| 3.8/1.8 | 46 |
| 3.4/1.6 | 46 |
| 3.5/1.7 | 46 |
| 3.7/1.7 |
| 700 | 47 |
| 3.5/1.7 | 47 |
| 3.6/1.7 | 47 |
| 3.7/1.8 | 46 |
| 3.4/1.6 | ||
Only |
| 9000 |
|
|
|
| |||||||||
| 725 | 48 |
| 3.7/1.8 | 48 |
| 3.8/1.8 | 47 |
| 3.5/1.7 | 47 |
| 3.6/1.7 | ||
|
|
|
|
|
|
| |||||||||
|
|
| 750 | 48 |
| 3.5/1.7 | 48 |
| 3.6/1.7 | 48 |
| 3.7/1.8 | 48 |
| 3.8/1.8 |
|
|
| 775 | 49 |
| 3.8/1.8 | 48 |
| 3.4/1.6 | 48 |
| 3.5/1.7 | 48 |
| 3.6/1.7 |
ALTITUDE RANGE | AVG GAS |
|
|
| SPECIFIC GRAVITY OF NATURAL GAS |
|
|
| |||||||
HEAT VALUE |
| 0.58 |
| 0.60 |
| 0.62 |
| 0.64 | |||||||
| (FT) | AT ALTITUDE | Orifice |
| Manifold | Orifice |
| Manifold | Orifice |
| Manifold | Orifice |
| Manifold | |
|
|
| (BTU/CU FT) | No. |
| Pressure | No. |
| Pressure | No. |
| Pressure | No. |
| Pressure |
|
|
| 600 | 46 | 3.6/1.7 | 46 | 3.7/1.8 | 46 | 3.8/1.8 | 45 | 3.7/1.8 | ||||
|
|
| 625 | 47 | 3.7/1.8 | 47 | 3.8/1.8 | 46 | 3.5/1.7 | 46 | 3.6/1.7 | ||||
U.S.A. |
| 9001 to | 650 | 47 | 3.4/1.6 | 47 | 3.6/1.7 | 47 | 3.7/1.8 | 47 | 3.8/1.8 | ||||
Only | 10,000 | 675 | 48 | 3.6/1.7 | 48 | 3.8/1.8 | 47 | 3.4/1.6 | 47 | 3.5/1.7 | |||||
|
|
| 700 | 48 | 3.4/1.6 | 48 | 3.5/1.7 | 48 | 3.6/1.7 | 48 | 3.7/1.8 | ||||
|
|
| 725 | 49 | 3.7/1.8 | 49 | 3.8/1.8 | 48 | 3.4/1.6 | 48 | 3.5/1.7 |
* Orifice numbers 43 are factory installed |
|
|
|
| |
SERVICE AND MAINTENANCE |
|
|
|
| |
| ! | WARNING |
| ||
| PROCEDURES |
|
| ||
|
|
| ELECTRICAL SHOCK, FIRE OR EXPLOSION |
| |
! | WARNING |
|
| ||
|
| ||||
| HAZARD |
|
| ||
|
|
| Failure to follow this warning could result in personal injury |
| |
FIRE, PERSONAL INJURY AND UNIT DAMAGE |
|
| |||
| or death, or property damage. |
| |||
HAZARD |
|
|
| ||
|
| Before servicing, disconnect all electrical power to furnace. |
| ||
Failure to follow this warning could result in personal injury, |
|
| |||
| Verify proper operation after servicing. |
| |||
death and/or property damage. |
|
| |||
|
|
|
|
The ability to properly perform maintenance on this equipment requires certain knowledge, mechanical skills, tools, and equipment. If you do not possess these, do not attempt to perform any maintenance on this equipment other than those procedures recommended in the User’s Manual.
312A
45