CAUTION

In cold climates provide protection against freeze-up.

THE HEATER SHOULD BE LOCATED IN AN AREA WHERE LEAKAGE OF THE TANK OR CONNECTIONS WILLNOT RESULT IN DAMAGE TO THE AREAADJACENT TO THE HEATER OR TO LOWER FLOORS OF THE STRUCTURE. When such locations cannot be avoided, a suitable drain pan should be installed under the heater, see fig. 1. The pan should have a minimum length and width of at least 2 inches greater than the diameter of the heater and should be piped to an adequate drain. Drain pans suitable for these heaters are available from your dealer.

Water heater life depends upon water quality, water pressure and the environment in which the water heater is installed. Water heaters are sometimes installed in locations where leakage may result in property damage, even with the use of a drain pan piped to a drain. However, unanticipated damage can be reduced or prevented by a leak detector or water shut-off device used in conjunction with a piped drain pan. These devices are available from some plumbing supply wholesalers and retailers, and detect and react to leakage in various ways:

Sensors mounted in the drain pan that trigger an alarm or turn off the incoming water to the water heater when leakage is detected.

Sensors mounted in the drain pan that turn off the water supply to the entire home when water is detected in the drain pan.

Water supply shut-off devices that activate based on the water pressure differential between the cold water and hot water pipes connected to the water heater.

Devices that will turn off the gas supply to a gas water heater while at the same time shutting off its water supply.

WARNING

DO NOT INSTALL THIS WATER HEATER DIRECTLY ON A CARPETED FLOOR. A FIRE HAZARD MAY RESULT. Instead the water heater must be placed on a metal or wood panel extending beyond the full width and depth by at least 3 inches (76.2mm) in any direction. If the heater is installed in a carpeted alcove or closet, the entire floor shall be covered by the panel. Also, see DRAINING.

WARNING

For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California’s Office of the State Architect, 400 P Street, Sacramento, CA 95814.

WATER CONNECTIONS

Refer to figure 1 for typical installation. A suitable pipe thread sealant must be used to prevent leakage.

WATER (POTABLE) HEATING AND SPACE

HEATING

1.All piping components connected to this unit for space heating applications shall be suitable for use with potable water.

2.Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system.

3.This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.

4.When the system requires water for space heating at temperatures higher than required for domestic water purposes, a tempering valve must be installed. Please refer to Figure 2 for suggested piping arrangement.

FIGURE2

CLOSED WATER SYSTEM

A closed system will exist if a back-flow preventer (check valve), or similar device is installed in the cold water line between the water heater and the street main (or well). Excessive pressure may develop due to the thermal expansion of heated water causing premature tank failure or intermittent relief valve operation. This type of failure is not covered by the limited warranty. An expansion tank may be necessary in the cold water supply to alleviate this situation, see fig. 1. Contact the local plumbing authority.

If the temperature and pressure relief valve on the appliance discharges periodically, this may be due to thermal expansion in a closed water supply system. Contact the water supplier or local plumbing inspector on how to correct the situation. Do not plug the temperature and pressure relief valve.

GAS CONNECTIONS

The minimum gas supply pressure is 5.0" W.C for natural gas (11.0" W.C. for propane).

THE HEATER IS NOT INTENDED FOR OPERATION AT HIGHER THAN 14.0'' WATER COLUMN SUPPLY PRESSURE. EXPOSURE TO HIGHER GAS SUPPLY PRESSURE MAY CAUSE DAMAGE TO THE CONTROL WHICH COULD RESULT IN FIRE OR EXPLOSION. If overpressure has occurred such as through improper testing of gas lines or emergency malfunction of the supply system, the control must be checked for safe operation. Make sure that the outside vents on the supply regulators and the safety vent valves are protected against blockage. These are parts of the gas supply system not the heater. Vent blockage may occur during ice storms.

IT IS IMPORTANT TO GUARD AGAINST CONTROL FOULING FROM CONTAMINANTS IN THE GAS WAYS. SUCH FOULING MAY CAUSE IMPROPER OPERATION, FIRE OR EXPLOSION.

All piping must comply with local codes and ordinances or with the National Fuel Gas Code (ANSI Z223.1/ NFPA-54) whichever applies. Copper and brass tubing and fittings (except tin lined copper tubing) shall not be used.

REFER TO FIG. 1 FOR CONNECTION DETAILS. BEFORE ATTACHING THE GAS LINE BE SURE THAT ALL GAS PIPE IS CLEAN ON THE INSIDE.

TO TRAP ANY DIRT OR FOREIGN MATERIAL IN THE GAS SUPPLY LINE, A DIRT LEG (SOMETIMES CALLED DRIP LEG) MUST BE INCORPORATED IN THE PIPING, FIG. 1. The dirt leg must be readily accessible. Install in accordance with recommendations of serving gas supplier. Refer to the current edition of National Fuel Gas Code, ANSI Z223.1/NFPA.

5

Page 5
Image 5
A.O. Smith GPSH, GPCR owner manual Water Connections, Water Potable Heating and Space, Closed Water System, GAS Connections

GPCR, GPSH specifications

A.O. Smith has long been a leader in the water heating industry, known for its innovation and commitment to quality. Among its standout products are the GPSH and GPCR series, which exemplify advanced technology and efficiency in water heating solutions.

The GPSH, or Gas Powered Storage Heater, is engineered to optimize energy usage while providing a continuous supply of hot water. This model features advanced thermostatic control, ensuring precise temperature management to meet user needs. Additionally, the GPSH boasts an impressive insulation system, reducing heat loss and resulting in improved energy efficiency. The inclusion of a high-efficiency gas burner allows for faster recovery times, meaning users can enjoy hot water on demand without extended wait times.

On the other hand, the GPCR, or Gas Powered Condensing Revolving Unit, is designed for commercial applications where high demand and energy efficiency are paramount. One of its main features is the condensing technology that recycles flue gases to enhance energy recovery. This leads to significant savings on energy bills and reduced environmental impact. The GPCR's advanced monitoring system provides real-time data on performance and efficiency, allowing for proactive maintenance and management.

Both models come equipped with A.O. Smith's proprietary safety features, including flame rollout switches and temperature and pressure relief valves, ensuring peace of mind for users. Their durable construction employs high-quality materials designed to withstand extreme operating conditions, further promoting longevity.

Installation and maintenance of both the GPSH and GPCR are straightforward, with user-friendly designs that simplify routine checks and servicing tasks. The compact nature of these units means they can fit into a variety of spaces, making them versatile options for both residential and commercial settings.

In summary, A.O. Smith's GPSH and GPCR series represent the pinnacle of water heating technology, combining efficiency, safety, and durability. With a focus on meeting the evolving demands of customers, these products are a reliable choice for anyone seeking effective solutions for their hot water needs. As the industry evolves, A.O. Smith continues to lead the way with its innovative designs and commitment to quality, ensuring users have access to the best water heating solutions available on the market.