WARNING

VENT HOOD(S) MAY BE

EXTREMELY HOT

DURING OPERATION.

FIGURE3

REFER TO FIG. 1 FOR CONNECTION DETAILS. BEFORE ATTACHING THE GAS LINE BE SURE THAT ALL GAS PIPE IS CLEAN ON THE INSIDE.

TO TRAP ANY DIRT OR FOREIGN MATERIAL IN THE GAS SUPPLY LINE, A DIRT LEG (SOMETIMES CALLED DRIP LEG) MUST BE INCORPORATED IN THE PIPING, FIG. 1. The dirt leg must be readily accessible. Install in accordance with recommendations of serving gas supplier. Refer to the latest edition of ANSI Z223.1.

To prevent damage, care must be taken not to apply too much torque when attaching gas supply pipe to thermostat gas inlet. The thermostat inlet has a pad for use with a backup wrench.

Apply joint compounds (pipe dope) sparingly and only to the male threads of pipe joints. Do not apply compound to the first two threads. Use compounds resistant to the action of liquefied petroleum gases. Do not use teflon tape on thermostat fittings.

CONNECTION OF GAS PIPE

1.When connecting gas pipe to unit, apply wrench to flange only. Note: Do not use wrench on gas valve or gas valve bracket.

2.PERFORM THE GAS LEAK TEST ANY TIME WORK IS DONE ONA GAS SYSTEM TOAVOID THE POSSIBILITY OF FIRE OR EXPLOSION WITH PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.

The Gas Leak Test is performed as follows: Paint pipe connections upstream of gas control with a rich soap and water solution to test for leaks before operating main burner. Bubbles indicate gas leak. To stop leak, tighten pipe connections. After piping connections are checked, turn on main burner. (See Lighting and Operating Installations in this manual or on water heater.) With main burner in operation, paint pipe joints (including flanges) and control inlet and outlet with rich soap and water solution. Bubbles indicate gas leak.

To stop leak, tighten flange screws, joints and pipe connections. Replace part if leak can't be stopped.

DISCONNECT THE APPLIANCE AND ITS INDIVIDUAL SHUT OFF VALVE FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY SUPPLY PRESSURE TESTING EXCEEDING 1/2 PSI (3.5 kPa). GAS SUPPLY LINE MUST BE CAPPED WHEN DISCONNECTED FROM THE HEATER. FOR TEST PRESSURES AT 1/2 PSI (3.5 kPa) OR LESS, THE APPLIANCE NEED NOT BE DISCONNECTED, BUT MUST BE ISOLATED FROM THE SUPPLY PRESSURE TEST BY CLOSING THE MAIN MANUAL GAS VALVE.

BEFORE PLACING THE HEATER IN OPERATION, CHECK FOR GAS LEAKAGE. USE SOAPAND WATER SOLUTION OR OTHER MATERIAL ACCEPTABLE FOR THIS PURPOSE. DO NOT USE MATCHES CANDLES, FLAME OR OTHER SOURCES OF IGNITION TO LOCATE GAS LEAKS.

RELIEF VALVE

A NEW TEMPERATURE AND PRESSURE RELIEF VALVE COMPLYING WITH THE STANDARD FOR RELIEF VALVES AND AUTOMATIC GAS SHUT OFF DEVICES FOR HOT WATER SUPPLY SYSTEMS, ANSI Z21.22 (LATEST EDITION) MUST BE INSTALLED IN THE HEATER IN THE MARKED OPENING PROVIDED. THE VALVE MUST BE OF A SIZE (INPUT RATING) THAT WILL BE ADEQUATE FOR YOUR SIZE HEATER.

Check the metal tag on the relief valve and compare it to the heater’s rating plate. The pressure rating of relief valve must not exceed the working pressure shown on the rating plate of the heater. In addition the hourly Btu rated temperature steam discharge capacity of the relief valve shall not be less than the input rating of the heater. NO VALVE IS TO BE PLACED

6

Page 6
Image 6
A.O. Smith GPS-75 owner manual Connection of GAS Pipe, Relief Valve

GPS-75 specifications

The A.O. Smith GPS-75 is a state-of-the-art gas water heater designed to deliver efficient and reliable hot water solutions to residential and light commercial users. With its sleek design and advanced technology, this unit stands out in the competitive water heating market.

One of the primary features of the GPS-75 is its impressive 75-gallon capacity, making it ideal for larger households or businesses that require a substantial volume of hot water. This water heater delivers a first-hour rating of up to 91 gallons, ensuring that you will always have enough hot water on demand, even during peak usage times.

The GPS-75 utilizes a high-efficiency gas burner that operates at an energy factor of 0.67, which helps to minimize energy costs while providing robust heating performance. This means that users can enjoy powerful hot water output without having to worry about skyrocketing energy bills. Additionally, the unit is equipped with a state-of-the-art electronic ignition system that ensures reliable startup and operation. This feature eliminates the need for a pilot light, enhancing safety and energy efficiency.

In terms of durability, the GPS-75 features a glass-lined interior which protects the tank from rust and corrosion. This adds to the unit's longevity and reduces the need for maintenance and replacement. The water heater also comes with insulating foam in the tank and a special temperature and pressure relief valve to enhance safety.

Another notable technology included in the GPS-75 is its advanced diagnostics feature. This system is designed to monitor and diagnose problems, allowing for quick troubleshooting and minimizing downtime. This is especially useful for service professionals and homeowners alike, as it facilitates efficient maintenance and reduces unexpected repair costs.

The GPS-75 also has an environmentally friendly design, meeting stringent energy efficiency guidelines. This aligns with the growing demand for sustainable solutions in modern homes and businesses.

In summary, the A.O. Smith GPS-75 gas water heater combines an impressive 75-gallon capacity, high efficiency, and advanced safety features to offer users a reliable and economical hot water solution. With its innovative technologies and durable construction, it stands as a strong contender in the water heating industry. Whether for residential or commercial use, the GPS-75 ensures that hot water is always available when needed.