A.O. Smith TWI 45-190 Troubleshooting table for general errors, Symptom, Cause, Solution, Remark

Models: TWI 35-130 TWI 45-190

1 62
Download 62 pages 8.68 Kb
Page 46
Image 46
Troubleshooting table for general errors

9.2

Troubleshooting table for general errors

 

 

 

 

 

 

 

 

 

 

 

 

 

Warning

 

 

 

 

 

 

 

 

Maintenance shall only be carried out by a service and maintenance engineer.

 

 

 

 

 

 

 

 

 

 

 

General errors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Symptom

Cause

 

Solution

 

Remark

 

 

 

 

 

 

 

 

Gas smell

Gas leakage

 

Warning

 

Warning

 

 

 

 

Immediately close the mains gas supply valve.

 

Immediately contact the installation engineer or the local gas

 

 

 

 

 

 

 

company.

 

 

 

 

Warning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not operate any switches.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warning

 

 

 

 

 

 

 

No open fire!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warning

 

 

 

 

 

 

 

Ventilate the area the device has been installed in.

 

 

 

 

 

 

 

 

 

 

 

Water leakage

Leaking water con-

 

Tighten the threaded connection.

 

Contact the installation engineer if the leakage has not been

 

 

nection (thread)

 

 

 

 

remedied.

 

 

 

 

 

 

 

 

 

 

 

Leakage of conden-

 

Check if condensate is discharged. Restore this if necessary.

 

 

 

 

 

sate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Leakage from

 

Find the leakage.

 

 

 

 

 

another water device

 

 

 

 

 

 

 

 

or pipe nearby

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Leakage of the tank

 

Consult the supplier and/or the manufacturer.

 

 

 

 

 

of the device

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Explosive ignition

Incorrectly set

 

Set the correct CO2-value(3.11 “Check and adjust the CO2-value”)

 

Contact the installation engineer if the ignition has not improved.

 

 

CO2-value

 

 

 

 

 

 

 

 

Contaminated burner

 

Clean the burner (10.4.2 “Clean the burner”).

 

 

 

 

 

 

 

 

 

 

 

 

Instruction manual - TWI 35-130 G/TWI 45-190 G

44

Page 46
Image 46
A.O. Smith Troubleshooting table for general errors, Instruction manual - TWI 35-130 G/TWI 45-190 G, Symptom, Cause