2. IftheVentTerminalisbeinginstalledontheoutsideofafinishedwall,itmay

the wall plate over the pipe to stop against the vent terminal. Place a bead

beeasiertomarkboththeinsideandoutsidewall.Aligntheholesbydrilling

of caulking (not supplied) around the gap between the pipe and cover

a hole through the center of the template from the inside through to the

plate. Apply enough to fill some of the gap between the pipe and wall.

outside.Thetemplatecannowbepositionedontheoutsidewallusingthe

Place some of the caulking on the back of the plate to hold it against the

drilled hole as a centering point for the template.

wall after installation. If the vent pipe is installed up to the wall, with a

 

coupling on the end against the wall opening, the pipe with the vent

3. A) MASONRY SIDE WALLS

terminal can be prepared for gluing before inserting through the wall. Slide

the pipe through the wall and insert into the coupling on the other side of

Chisel an opening approximately one half inch (1.3 cm) larger than

the wall, making sure that the vent terminal ends up pointed in the correct

the marked circle.

position, see Figure 18.

 

B) WOODEN SIDE WALLS

 

Drill a pilot hole approximately one quarter inch (0.64 cm) outside of

 

the marked circle. This pilot hole is used as a starting point for a

 

saws-all or sabre saw blade. Cut around the marked circle staying

 

approximately one quarter inch (0.64 cm) outside of the line. (This

 

will allow the vent to easily slide through the opening. The resulting

 

gap will be covered up by the Vent Terminal cover plate.) Repeat this

 

step on inside wall if necessary.

 

SEQUENCE OF INSTALLATIONS, FIGURE 18

 

Cut a length of PVC pipe about 3.5 inches (8.9 cm) longer than the wall

VENT TERMINATION - FIGURE 18.

thickness at the opening. Glue the vent terminal to this section of pipe. Slide

CAUTION

LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.

POWER VENT WIRING SCHEMATIC - FIGURE 19.

20

Page 20
Image 20
A.O. Smith W/HOT instruction manual Vent Termination Figure, Power Vent Wiring Schematic Figure

W/HOT specifications

A.O. Smith, a leading manufacturer of water heating solutions, has made its mark in the industry with innovative products that combine efficiency, reliability, and advanced technology. Among its standout offerings is the A.O. Smith W/HOT series, designed to meet the diverse needs of residential and commercial customers.

The W/HOT series showcases a variety of tankless water heaters characterized by their ability to provide endless hot water on demand. Unlike traditional tank water heaters, which can run out of hot water during heavy usage, the W/HOT series ensures a constant supply, making it an ideal choice for families and businesses with high hot water needs. This feature not only enhances convenience but also optimizes energy usage by eliminating the standby heat loss associated with storage tanks.

One of the key technologies integrated into the W/HOT series is the microprocessor control system. This intelligent technology allows the unit to monitor water usage patterns and adjust operation accordingly. By optimizing heating cycles based on actual demand, this feature helps improve energy efficiency, resulting in lower utility bills without compromising performance.

The W/HOT series also incorporates advanced heat exchanger technology, enabling rapid heating of water as it passes through the system. This means minimal wait time for hot water and reduced energy consumption, as the unit only heats water when it is needed. The heat exchangers are designed for durability and effective heat transfer, helping to extend the overall lifespan of the unit.

Safety is a top priority in the design of A.O. Smith water heaters. The W/HOT series is equipped with multiple safety features, including a built-in thermal shut-off switch and safety sensors that prevent overheating. Additionally, the units are designed to comply with industry standards and regulations, ensuring peace of mind for users.

Installation flexibility is another defining characteristic of the W/HOT series. These tankless water heaters can be installed in various locations, requiring minimal space compared to traditional units. Their compact design makes them suitable for tight spaces, such as closets or utility rooms.

Overall, the A.O. Smith W/HOT series represents a commitment to innovation and quality in water heating solutions. Its combination of tankless design, advanced technology, and safety features makes it an excellent choice for those seeking efficient and reliable hot water access. Whether for residential or commercial use, A.O. Smith continues to lead the way in delivering top-tier water heating solutions that meet the evolving needs of consumers.