INSTALLATION

FIREBOX LINER PANELS

The Aarrow Ecoburn Wood and Multifuel stoves use firebox liner panels to the sides and back of the firebox. The throat plate sits on top of the side and rear panels. These should come fitted to your stove, if however they are not proceed as follows to fit them as follows -

•Open the fire door.

•Remove the two round front fuel retaining bars, by lifting one end free of the bracket and sliding the remaining end out from the bracket.

•Set the small liner(s) into the back of the fire.

•Insert side liner panels. (See Fig. 10).

•Fit the throat plate with the single bend and two cut outs to the front facing up. The projecting lugs sit on top of the side liners. The long centre tab on the back edge rests on the rear liners.The shorter turn-down tabs against the vertical face.(See Fig. 11 & 12 ).

•Replace the front fuel retainer bars.

Note: Neither the rear firebox liners nor the side firebox liners are "handed", both faces are suitable for direct contact with the fire.

Note: Cracking of lining panels does not effect efficiency.

Fig. 9. Overall View Of Liners & Throat

Plate.

Fig. 10. Liners inserted

Fig. 11. Inserting the throat plate

Fig. 12. Liners & throat plate correctly fitted

16

Aarrow Ecoburn Wood & Multifuel Stoves