Remove front fuel retainer bars.
Set the four linings on the side ledges on either side of the firebox. See Fig 5.
Set the three 197mm x 230mm rectangular linings on the upper surface of the grate bar channel at the rear of
the firebox.
To keep the back linings in position, locate the stainless steel locking channel centred on the top edge of three
rear linings.
Fit the throat plate with the tab at the front marked "Throat plate" pointing down, with the projecting lugs on
the sides of the throat plate resting on the top of the steel guides, and the bend at the back resting against the
rear firebox lining.
Replace the front fuel retainer bars.
Note: Neither the rear linings nor the side linings are handed and both faces are suitable for direct contact
with the fire.
5. THROAT PLATE INSPECTION
The throat plate for all fires type consists of a profiled steel plate with "drop down" facility for inspection
purposes.
To "drop" the throat plate (Fig 6), engage the operating tool behind the downstand tab marked "throat plate" and
pull the plate frontward until its forward lugs drop into the cut-away at the front of the side panel. Check the
upper surface for soot, ash build-up, etc. Reverse the procedure to return the throat plate to the working position.
Warning: If the fire is operated with the throat plate in the down position the air wash will not operate
effectively.
Figure 6
Throat Plate position for Si only
THROAT PLATE
OPERATING TOOL
THROAT PLATE GUIDE