6
PARAMETERSPROGRAM DESCRIPTION

Current (Amperes)

Voltage (Volts)

Desulphation Soft Start Bulk Absorption

Recovers a
sulphated battery
Tests the battery
condition Bulk charge Peak charge with
minimal fluid loss

MULTI XS 25000

MODE Desulphation Soft Start Bulk Absorption
NORMAL
or
RECOND
YES Max 10 A for 4 h until the
voltage reaches 12 V.
25 A for max 20 h. 14.4 V until 4 h after the
current dropped to 3 A,
max 12 h.
SUPPLY

XS 25000

MODE Desulphation Soft Start Bulk Absorption
PRESET YES Max 10 A for 4 h until the
voltage reaches 12 V.
25 A for max 20 h. 14.4 V until 4 h after the
current dropped to 3 A,
max 12 h.

MULTI XT 14000

MODE Desulphation Soft Start Bulk Absorption
NORMAL
or
RECOND
YES Max 6 A for 4 h until the
voltage reaches 24 V.
14 A for max 20 h. 28.8 V until 4 h after the
current dropped to 2 A,
max 12 h.
SUPPLY

XT 14000

MODE Desulphation Soft Start Bulk Absorption
PRESET YES Max 6 A for 4 h until the
voltage reaches 24 V.
14 A for max 20 h. 28.8 V until 4 h after the
current dropped to 2 A,
max 12 h.