PARAMETERS

PROGRAM DESCRIPTION

 

 

Desulphation

Soft Start

Bulk

Absorption

 

(Volts)

 

 

 

 

(Amperes)

Voltage

Recovers a

Tests the battery

Bulk charge

Peak charge with

sulphated battery

condition

minimal fluid loss

 

 

 

 

 

Current

 

 

 

 

 

MULTI XS 25000

MODE

Desulphation

Soft Start

Bulk

Absorption

NORMAL

YES

Max 10 A for 4 h until the

25 A for max 20 h.

14.4 V until 4 h after the

or

 

voltage reaches 12 V.

 

current dropped to 3 A,

RECOND

 

 

 

max 12 h.

 

 

 

 

 

SUPPLY

 

 

 

 

XS 25000

 

 

 

MODE

Desulphation

Soft Start

Bulk

Absorption

PRESET

YES

Max 10 A for 4 h until the

25 A for max 20 h.

14.4 V until 4 h after the

 

 

voltage reaches 12 V.

 

current dropped to 3 A,

 

 

 

 

max 12 h.

MULTI XT 14000

 

 

 

MODE

Desulphation

Soft Start

Bulk

Absorption

NORMAL

YES

Max 6 A for 4 h until the

14 A for max 20 h.

28.8 V until 4 h after the

or

 

voltage reaches 24 V.

 

current dropped to 2 A,

RECOND

 

 

 

max 12 h.

 

 

 

 

 

SUPPLY

 

 

 

 

XT 14000

 

 

 

MODE

Desulphation

Soft Start

Bulk

Absorption

PRESET

YES

Max 6 A for 4 h until the

14 A for max 20 h.

28.8 V until 4 h after the

 

 

voltage reaches 24 V.

 

current dropped to 2 A,

 

 

 

 

max 12 h.

6

Page 6
Image 6
AB Soft XS 25000, XT 14000 Volts Amperes Voltage, Current, Desulphation Soft Start Bulk Absorption, Normal YES, Preset YES