Recond (Lamp 5) (only on MULTI XS 25000 and MULTI XT 14000)

This mode is used to recover deeply discharged flooded batteries. Recondition of deep discharged batteries. The voltage increases with reduced current for a limited time period. The higher voltage starts some gassing and mixing of the acid, which is beneficial for both battery capacity and expected life. Note that the battery could emit explosive gas during Recond. Recond is performed between Analysis and Maintenance.

INDICATORS

Lamp Description

0Fault mode, the charging is discontinued. For fault causes, see below.

1Start mode

2Bulk charging

3Absorption charging

4Maintenance charging

5Supply (Only on MULTI XS 25000 and MULTI XT 14000)

6Recond reconditioning of completely discharged batteries. (Only on MULTI XS 25000 and MULTI XT 14000)

ACharging without temperature compensation.

BMains voltage connected

CNormal (Only on MULTI XS 25000 and MULTI XT 14000)

DSupply (Only on MULTI XS 25000 and MULTI XT 14000)

ERecond (Only on MULTI XS 25000 and MULTI XT 14000)

Fault mode

The charger goes to fault mode if the time for gradual start has been exceeded or if the battery’s self-discharge is too high.