Analysis | Recond | Float | Pulse |
Tests whether the | Reconditioning of | Maintenance for | Maintenance for | |
battery retains | maximum | maximum | ||
a drained battery | ||||
the energy | performance | battery life | ||
|
Analysis | Recond | Float | Pulse |
Warning indication if | Max 15.9 V and 5 A | 13.8 V with max 7 A for | Pulse start at 12.9 V, |
voltage drops to 12.6 V | for 4 h for deeply | max 10 days. | max voltage 14.4 V. |
in 2 minutes. | discharged batteries. |
|
|
| Otherwise for 30 min- |
|
|
| utes (only in Recond |
|
|
| mode). |
|
|
|
| 13.8 V max 300 W. |
|
Analysis | Recond | Float | Pulse |
Warning indication if |
| 13.8 V with max 7 A for | Pulse start at 12.9 V, |
voltage drops to 12.6 V |
| max 10 days. | max voltage 14.4 V. |
in 2 minutes. |
|
|
|
|
|
|
|
Analysis | Recond | Float | Pulse |
Warning indication if | Max 31.8 V and 3 A | 27.6 V with max 4 A for | Pulse start at 25.8 V, |
voltage drops to 25.2 V | for 4 h for deeply | max 10 days. | max voltage 28.8 V. |
in 2 minutes. | discharged batteries. |
|
|
| Otherwise for 30 min- |
|
|
| utes (only in Recond |
|
|
| mode). |
|
|
|
| 27.6 V max 300 W. |
|
|
|
|
|
Analysis | Recond | Float | Pulse |
Warning indication if |
| 27.6 V with max 4 A for | Pulse start at 25.8 V, |
voltage drops to 25.2 V |
| max 10 days. | max voltage 28.8 V. |
in 2 minutes. |
|
|
|