Accton Technology E0398-R01 Null Modem, Optional Management Software, EtherHub 1500 System, DB25

Models: EH1502S 150858-101 E0398-R01

1 9
Download 9 pages 1.1 Kb
Page 9
Image 9
DB25

EtherHub 1500 System

DB9 Serial Port to RJ-45 Converter Connector Pin Assignment

Description

RJ-45 Pin

EH1502S

Mapping

DB9

 

DTR (Data Terminal Ready)

1

4

RxD (Received Data)

2

2

TxD (Transmitted Data)

3

3

SG (Signal Ground)

4

5

RI (Ring Indicator)

5

9

CTS (Clear-to-Send)

6

8

RTS (Request-to-Send)

7

7

DCD (Data Carrier Detected)

8

1

DSR (Data Set Ready)

NC

6

DB9 PC's COM Port to RJ-45 Converter Connector Pin Assignment

Description

RJ-45 Pin

EH1502

Mapping

DB9

 

DTR (Data Terminal Ready)

1

6

RxD (Received Data)

2

3

TxD (Transmitted Data)

3

2

SG (Signal Ground)

4

5

RI (Ring Indicator)

5

9

CTS (Clear-to-Send)

6

7

RTS (Request-to-Send)

7

8

DCD (Data Carrier Detected)

8

1

DSR (Data Set Ready)

NC

4

DB25 RS232 to RJ-45 Converter Connector Pin Assignment

Description

RJ-45 Pin

EH1502S

Mapping

DB25

 

DTR (Data Terminal Ready)

1

20

RxD (Received Data)

2

3

TxD (Transmitted Data)

3

2

SG (Signal Ground)

4

7

RI (Ring Indicator)

5

22

CTS (Clear-to-Send)

6

5

RTS (Request-to-Send)

7

4

DCD (Data Carrier Detected)

8

8

DSR (Data Set Ready)

NC

6

Connection from Hub's 9-Pin Serial Port to PC's 9-Pin COM Port

 

Hub's 9-Pin

 

CCITT Signal

PC's 9-Pin

 

Serial Port

 

COM Port

 

 

 

 

1 DCD

---

---- DCD --------

1

2

RXD

<-

---- TXD ---------

3

3

TXD

---

---- RXD ------

>

2

4

DTR

---

---- DSR ------

>

6

5

SGND

---

---- SGND ------

5

6

DSR

---

---- DTR --------

4

7

RTS

---

---- CTS ------

>

8

8

CTS

<-

----- RTS --------

7

9

RI

---

---- RI -----------

9

Advanced Reference Guide

Connection from Hub's 9-Pin Serial Port to Modem's 25-Pin DCE Port

Hub's 9-Pin

 

CCITT Signal

Modem's 25-Pin

Serial Port

 

COM Port

 

 

 

1

<--

---- DCD -------

8

2

<--

---- RXD -------

3

3

---

----- TXD ------

>

2

4

---

----- DTR ------

>

20

5

---

----- SGND -----

7

6

<--

---- DSR -------

6

7

---

----- RTS ------

>

4

8

<--

---- CTS -------

5

9

<--

---- RI -------

 

22

Connection from Hub's 9-Pin Serial Port to PC's 25-Pin DTE Port

 

Hub's 9-Pin Serial Port

Null Modem

PC's 25-Pin DTE Port

1 DCD

1

1

8

DCD

2

RXD

2

3

3

TXD

3

TXD

3

2

2

RXD

4

DTR

4

8

20

DTR

5

SGND

5

20

7

SGND

6

DSR

6

7

6

DSR

7

RTS

7

4

4

RTS

8

CTS

9

5

5

CTS

9

RI

20

6

22

RI

Optional Management Software

SW6120: AccView EtherHub Manager for SunNet Manager

SW6121: AccView EtherHub Manager for OpenView/Windows

SW6122: AccView EtherHub Manager for OpenView/Unix

SW6122: AccView EtherHub Manager for NMS

SW6130: Network Mangement Support Modules for NMM

SW7300: EtherHub 1500 Security Module

12

13

Page 9
Image 9
Accton Technology E0398-R01 Null Modem, Optional Management Software, EtherHub 1500 System, Advanced Reference Guide, DB25