CE Mark Declaration of Conformance for EMI and Safety (EEC)

This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the compliance with these Directives, the following standards were applied:

RFI Emission: • Limit class A according to EN 55022:1998

 

• Limit class A for harmonic current emission according to EN 61000-3-2/1995

 

• Limitation of voltage fluctuation and flicker in low-voltage supply system

 

 

according to EN 61000-3-3/1995

Immunity:

Product family standard according to EN 55024:1998

 

• Electrostatic Discharge according to EN 61000-4-2:1995

 

 

(Contact Discharge: ±4 kV, Air Discharge: ±8 kV)

 

Radio-frequency electromagnetic field according to EN 61000-4-3:1996

 

 

(80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m)

 

Electrical fast transient/burst according to EN 61000-4-4:1995 (AC/DC power

 

 

supply: ±1 kV, Data/Signal lines: ±0.5 kV)

 

• Surge immunity test according to EN 61000-4-5:1995

 

 

(AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV)

 

• Immunity to conducted disturbances, Induced by radio-frequency fields:

 

 

EN 61000-4-6:1996 (0.15 - 80 MHz with 1 kHz AM 80% Modulation: 3 V/m)

 

• Power frequency magnetic field immunity test according to

 

 

EN 61000-4-8:1993

 

 

(1 A/m at frequency 50 Hz)

 

• Voltage dips, short interruptions and voltage variations immunity test

 

 

according to EN 61000-4-11:1994 (>95% Reduction @10 ms, 30%

 

 

Reduction @500 ms, >95% Reduction @5000 ms)

LVD:

EN 60950 (A1/1992; A2/1993; A3/1993; A4/1995; A11/1997)