STOPPING THE GENERATOR
To stop this generator:
1.Turn off all connected electrical devices and then unplug them.
2.Switch the circuit breaker to the “off” position.
3.Allow this generator to run for several more minutes with no electrical devices connected to help stabilize the temperature of this generator.
4.Set the engine switch to the “off” position.
5.Turn the fuel valve to the “off” position.
Allow this generator to cool down before touching areas that become hot during operation.
Allowing gasoline to sit in this generator's fuel tank for extended time without use can increase the difficulty in starting this generator in the future. Never store this generator for extended time with gasoline in the fuel tank.
MAINTENANCE/CARE
Proper routine maintenance of this generator is essential for safe, economical, and
STOP!
If you have questions about any maintenance procedures described in this manual, call
Time.
Never perform maintenance procedures while this generator is running. Allow this generator to cool before commencing any maintenance procedures. Keep heat, sparks and flame away.
Improper maintenance and/or failure to correct any problems prior to operating this generator can cause a malfunction which could cause death or serious injury. Always follow the inspection and maintenance recommendations and schedules in this manual.
Recommended Maintenance Schedule
|
| Each Use | Every Month or | Every 3 Months or | Every 6 Months or | Every Year or |
|
|
| Each 20 Hrs | Each 50 Hrs | Each 100 Hrs | Each 300 Hrs |
Engine Oil | Check Level | X |
|
|
|
|
| Replace |
| X |
|
|
|
Air Filter | Check | X |
|
|
|
|
| Clean |
|
| X |
|
|
Fuel Filler Cap | Clean |
|
|
| X |
|
Spark Plug | Check/Clean |
|
|
| X |
|
Fuel Tank | Verify Gas Level | X |
|
|
|
|
| Clean |
|
|
|
| X |
Figure 10 - Recommended maintenance schedule
Model | 19 |