AC Adapter

Item

 

Specification

 

 

 

Frequency variation range

47 - 63

 

(Hz)

 

 

 

 

 

Nominal voltages (Vrms)

90 - 264

 

 

 

Inrush current

The maximum inrush current will be less than 50A and 100A when

 

the adapter is connected to 100Vac(60Hz) and 240Vac(50Hz)

 

respectively.

 

 

 

Efficiency

High efficiency 85% minimum, at 100~240Vac AC input, full load,

 

warm-up condition.

 

 

 

Output Ratings (CV mode)

 

 

 

 

DC output voltage

Offers constant voltage 19.0V output source with 150W max output

 

power capacity.

 

 

Noise + Ripple

300mvp-pmax (20MHz bandwidth) for resistor load

 

 

 

Output current

0 A (min.)

3.5A (max.)

 

 

 

Output Ratings (CC mode)

 

 

 

 

 

DC output voltage

18.0 ~ 20.0

 

 

 

 

Constant output

7.9A

 

 

 

 

Dynamic Output Characteristics

 

 

 

Start-up time

3 sec. (@115 Vac and 230Vac full load)

 

 

Hold up time

5ms min. (@115 Vac input, full load)

 

 

 

Over Voltage Protection

25V

 

(OVP)

 

 

 

 

Short circuit protection

Output can be shorted without damage, and auto recovery

 

 

Electrostatic discharge

15kV (at air discharge)

(ESD)

8kV (at contact discharge)

 

 

 

Dielectric Withstand Voltage

 

 

 

 

Primary to secondary

4242 Vdc for 1 second-

 

 

Leakage current

60uA at 240Vac/60Hz

 

 

Regulatory Requirements

1. FCC class B requirements (USA)

 

2. VDE class B requirements (German)

 

3. VCCI classII requirements (Japan)

 

 

 

Power Management

 

 

 

 

 

ACPI Mode

 

Power Management

 

 

Mech. Off (G3)

All devices in the system are turned off completely.

 

 

Soft Off (G2/S5)

OS initiated shutdown. All devices in the system are turned off

 

completely.

 

 

 

Working (G0/S0)

Individual devices such as the CPU and hard disk may be power

 

managed in this state.

 

 

Sleeping State (S3)

CPU Power Down

 

VGA Power Down

 

PCMCIA Suspend

 

Audio Power Down

 

Hard Disk Power Down

 

Super I/O Power Down

 

 

Sleeping State (S4)

Also called Hibernate state. System saves all system states and data

 

onto the disk prior to power off the whole system.

 

 

 