Acer AL1912 manual Protection function, AC-DC Output Specification

Models: AL1912

1 62
Download 62 pages 31.4 Kb
Page 27
Image 27

AC-DC Output Specification

 

Tolerance

Output Current

Voltage Tolerance

 

 

 

 

Output Voltage

---

MIN

MAX

 

 

 

 

 

 

+5Vdc

+5 /-3 %

0.05A

1.5A

4.85~5.25V dc

 

 

 

 

 

+15Vinv

+35/-5 %

0A

2A

20~14.3Vdc

 

 

 

 

 

+5Vaudio

±5%

0A

0.6A

4.75~5.25Vdc

 

 

 

 

 

Ripple

1.Measured at DC

---

1%

+5Vdc:50mVp-p

output terminals which

+15Vinv:150mVp-p

 

are paralleled with a

 

 

 

10uf Ecap &0.1uf

 

 

 

Noise

Ceramic cap.

---

3%

+5Vdc:150mVp-p

2.Band width is limited

+15Vinv:450mVp-p

 

 

 

 

within 20MHz.

 

 

 

 

 

 

 

 

 

 

 

 

50~100% or 100~50%

 

 

 

Dynamic Load Regulation

load change of any DC

---

±5%

---

output @50% duty of

 

 

 

 

 

1MHz (min.)

 

 

 

 

 

 

 

 

Over / Under Shoot

@ Power line on/off

---

±5%

---

 

 

 

 

 

*+5Vdc load regulation test: the +15Vinv loading at 2.0A

*+15Vinv load regulation test: the +5Vdc loading at 1.5A

Protection function

1)SCP: Short circuit protection must be acted on both outputs

2)OPP: Should be protected when output power consumption is within 60W ~ 75W

- 27 -