SPE C N O.
MT 220 WW 01 V. 0
PAG E
14/23
ALL RIGH TS RESE RVED ANY PORTION O F THIS DOCUMENT SHALL NOT BE REPRODUC ED, COP IED, O R TRANSF ORMED
TO ANY OTHER FORMS W ITHOUT
PRIOR
WRITTEN
PERMISS ION FROM INNOLUX DISPLAY CORP ORATION.
Note 2:
Test equipment: AS-114B
Note 3:
The voltage shown above should be applied to the lamp for more than 1 second after startup.
Otherwise, the lamp may no t be turned on normally.
Note 4:
Inverter should provide more than min. value, and then lamp cou ld be completely turned on.
Note 5:
Lamp frequency may produce interference with horizontal synch ronous frequen cy and this
may cau se line flow on the display. The refore lamp frequency shall be detached from the
horizontal synchronous frequency and its harmonics as far as possible in order to avoid
interference.
Note 6:
Lamp life definition: The brightne ss of lamp becomes 50% of the initial brightness or not
normal lighting.
Backlight connector : 35001 HS-02L
Pin no. Symbol Function Remark
1 VIH Lamp high v oltage input Cable color: Pink
2 VIL Lamp low v oltage input Cable color: White
3 VIH Lamp high v oltage input Cable color: Blue
4 VIL Lamp low v oltage input Cable color: Black