Acer B243W manual Electrical Requirements, Standard Test Conditions

Models: B243W

1 56
Download 56 pages 41.06 Kb
Page 8
Image 8

Electrical Requirements

Standard Test Conditions

All tests shall be performed under the following conditions, unless otherwise specified.

Ambient light

Dark room (< 1 cd/m2)

 

 

Viewing distance

35-50cm

Warm up time

30 minutes

 

 

Analog Input signal

700 mVss

Control temperature

6500° K

Brightness control

Set to Factory preset value (cut off raster)

 

Set to The value under user mode, which allows that the brightest

User contrast control

two of 32 linear distributed gray-scales (0700mv) can be

 

distinguished.

Picture position and size

Factory preset value

 

 

Viewing angle

90°+/-20 ° H and 90°+/-10° V

AC Supply voltage

230V± 5, 50±3Hz

Ambient temperature

20+5

Humidity

65% ± 20%

Display mode

1920x1200, 60 Hz, all white

 

 

e-color mode

Set to “User” mode

Measurement systems

The units of measure stated in this document are listed below: 1 gamma = 1 nano tesla

1 tesla = 10,000 gauss cm = in x 2.54

Lb = kg x 2.2

Degrees F = [°C x 1.8] + 32 Degrees C = [°F - 32]/1.8 u' = 4x/(-2x + 12y + 3)

v' = 9y/(-2x + 12y + 3)

x = (27u'/4)/[(9u'/2) - 12v' + 9] y = (3v')/[(9u'/2) - 12v' + 9] nits = cd/(m2) = Ft-L x 3.426 lux = foot-candle x 10.76

8

Page 8
Image 8
Acer B243W manual Electrical Requirements, Standard Test Conditions