Appendix C: Using the Adaptec RAID Configuration Utility ●84
SCSI-specific Controller SettingsIn addition to the general settings listed on page 82, your Adaptec SCSI controller has SCSI-
specific settings that can be modified if required. 
To modify SCSI-specific settings, select SCSI Configuration from the SCSISelect main menu.
SCSI Device Settings
You can use SCSISelect to modify some of the settings on the SCSI devices connected to your 
SCSI controller. 
To modify SCSI device settings, select SCSI Configuration from the SCSISelect main menu, 
then select Additional Options. Devices are listed by SCSI ID. (To find the SCSI ID for a 
specific device, see Formatting and Verifying Disk Drives on page 85.)
For the best device performance, don’t change the default settings.
Note: Default settings are shown in bold type. 
SCSI Channel Interface Settings
Note: Default settings are shown in bold type. 
Option Description
Maximum 
Tran sfe r Ra te 
Shows the maximum data transfer rate that the SCSI channel supports. 
Enable 
Disconnection
When enabled, the SCSI device can disconnect from the SCSI channel. Default is 
Yes (enabled). 
Initiate Wide 
Negotiation
When enabled, the SCSI channel attempts 16-bit data transfer instead of 8-bit 
data transfer. Default is Yes (enabled).
QAS When enabled, QAS (Quick Arbitration and Selection) is used to eliminate 
overhead and speed up data transfers on the SCSI bus. Default is No (disabled).
Note—Adaptec recommends that you do not enable QAS if you are using an 
enclosure that supports Ultra320 expanders.
Packetized When enabled, SCSI packetization (encapsulation) is used to reduce overhead 
and speed data transfer. Default is Yes (enabled).
Option Description
Controller SCSI 
Channel ID
Sets the controller’s SCSI ID. Adaptec recommends that you leave the controller 
set to the default (7), which gives it the highest priority on the SCSI channel.
SCSI Parity 
Checking
When enabled, the controller verifies the accuracy of data transfer on the SCSI 
channel. Disable only if the controller is connected to any SCSI device that does 
not support SCSI parity. Default is enabled.
Controller SCSI 
Channel 
Termination
Sets termination on the controller. Adaptec recommends that you retain the 
default setting (auto mode).