ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

DLP-556

Page 1 of 3

DS1 PM CONFIGURATION

Summary: This procedure provides instructions for assigning thresholds for each DS1 in the Soneplex Broadband system. You can also view or edit the DS1 Performance Monitoring configuration for each DS1 in the Soneplex Broadband system from this screen. Not all modules support Performance Monitoring.

Note: A “toggle” field type means the user can press the space bar to view and select the next option that is described; or the user can press the “R” key to view and select the previous option. An “input” field type means the user must type an entry in the field according to the parameters described. A “fixed” field is locked, and cannot be changed by the user.

Note: Edits can be made in the configuration database in one of two ways: 1) If the complete field is highlighted, use the space bar to toggle forward or the “R” key to reverse toggle through the options for that field. 2) If only the first space or the field is highlighted, type in the data that applies to that field.

Note: Edits to the configuration database can be saved after each change in one of two

ways: 1) Press an arrow key and then Enter or Return once; or 2) Press Enter or Return twice after all selections and entries are made in the screen but before leaving the screen. If the entries have been accepted, a message “Configuration Successful… Press Any Key To Continue” appears on the screen.

Note: Press CONTROL-A for help information on moving around and editing fields.

1.Use the arrow keys to select Performance Monitoring from the Main Menu. Press Enter or Return. A Performance Monitoring menu appears.

2.Use the arrow keys to select DS1 PM Configuration from the PM Configuration menu. Press Enter or Return. A DS1 PM Configuration screen is shown in Figure 556-1.

3.Move to the Group toggle field. Select group number 1, 2, 3, 4, 5, 6, or 7.

4.Move to the Slot toggle field. Select slot number 1, 2, 3, or 4. Reference: TAD-106Access Identifier

5.Move to the Mon Type Threshold toggle fields. Enter the value for each field that you wish to change based on ranges and default values for each Mon Type listed in Table 556-1. Ranges are also listed at the bottom of the DS1 PM Configuration screen.

Reference: TAP-102Performance Monitoring Reports Description

2-180

© 2000, ADC Telecommunications, Inc.