Page 3 of 3
Table
LINE/PATH (NEND) THRESHOLDS
|
|
| DAILY VALID | ||
| MON TYPE | DEFAULT | VALID RANGE | DAILY DEFAULT | RANGE |
|
|
|
|
|
|
| FCP | 5 | 1 to 5 | 480 | 1 to 480 |
|
|
|
|
|
|
| CVL | 13340 | 1 to 16383 | 133400 | 1 to 1048575 |
|
|
|
|
|
|
| ESL | 65 | 1 to 900 | 648 | 1 to 65535 |
|
|
|
|
|
|
| SESL | 10 | 1 to 63 | 100 | 1 to 4095 |
|
|
|
|
|
|
| LOSS | 10 | 1 to 63 | 100 | 1 to 4095 |
|
|
|
|
|
|
| CVP | 13340 | 1 to 16383 | 133400 | 1 to 1048575 |
|
|
|
|
|
|
| ESP | 65 | 1 to 900 | 648 | 1 to 65535 |
|
|
|
|
|
|
| SESP | 10 | 1 to 63 | 100 | 1 to 4095 |
|
|
|
|
|
|
| UASP | 10 | 1 to 63 | 100 | 1 to 4095 |
|
|
|
|
|
|
| SASP | 10 | 1 to 63 | 100 | 1 to 4095 |
|
|
|
|
|
|
| AISSP | 10 | 1 to 63 | 100 | 1 to 4095 |
|
|
|
|
|
|
|
| LINE/PATH (FEND) THRESHOLDS |
| ||
|
|
| DAILY VALID | ||
| MON TYPE | DEFAULT | VALID RANGE | DAILY DEFAULT | RANGE |
|
|
|
|
|
|
| 5 | 1 to 5 | 480 | 1 to 480 | |
|
|
|
|
|
|
| 65 | 1 to 63 | 648 | 1 to 65535 | |
|
|
|
|
|
|
| 13340 | 1 to 16383 | 133400 | 1 to 1048575 | |
|
|
|
|
|
|
| 65 | 1 to 900 | 100 | 1 to 65535 | |
|
|
|
|
|
|
| 10 | 1 to 63 | 100 | 1 to 4095 | |
|
|
|
|
|
|
| 10 | 1 to 63 | 100 | 1 to 4095 | |
|
|
|
|
|
|
| 10 | 1 to 63 | 100 | 1 to 4095 | |
|
|
|
|
|
|
| 10 | 1 to 63 | 100 | 1 to 4095 | |
|
|
|
|
|
|
|
| INTERNAL PARAMETER THRESHOLDS |
| ||
|
| MON TYPE | DEFAULT | VALID RANGE |
|
|
|
|
|
|
|
|
| CVs per SESL | 1544 | 1544 to 8000 |
|
|
|
|
|
|
|
|
| CVs per SESP | 320 | 320 to 333 |
|
|
|
|
|
|
|
|
| CVs per | 320 | 320 to 333 |
|
|
|
|
|
|
|
Note: refer to
© 2000, ADC Telecommunications, Inc.