| Page 2 of 3 |
6. Move to the Mon Type Alarms toggle fields. The following selections are possible: | ||
• | Critical | Allows notification of all Critical, Major, Minor, and Event alarms as they |
| occur. |
|
• | Major | Allows notification of all Major, Minor, and Event alarms as they occur. |
• | Minor | Allows notification of all Minor and Event alarms as they occur. |
• | Event | Allows notification of all events as they occur. |
Reference: | ||
7.Assign the selections by pressing Enter or Return.
8.Repeat Steps 3 through 7 for each applicable DS1 signal in the chassis.
Note: Pressing
Stop! You have completed this procedure.
|
|
| DS1 PERFORMANCE MONITORING CONFIGURATION |
|
| |||||
|
| Group: 1 | Circuit: 1 | Circuit ID: |
|
|
|
| ||
| 15 MINUTE | DAILY |
|
|
| 15 MINUTE | DAILY | |||
MON | ============== | ================ | MON | ============== | ================ | |||||
TYPE | THRSH ALM LVL | THRSH | ALM LVL | TYPE | THRSH ALM LVL | THRSH | ALM LVL | |||
==== | ===== ======== | ======= | ======== | ======== | ===== ======== | ======= | ======== | |||
FCP | 5 | EVENT | 480 | EVENT | AISSP | 10 | EVENT | 100 | EVENT | |
CVL | 13340 | EVENT | 133400 | EVENT | 5 | EVENT | 480 | EVENT | ||
ESL | 65 | EVENT | 648 | EVENT | 65 | EVENT | 648 | EVENT | ||
SESL | 10 | EVENT | 100 | EVENT | 13340 EVENT | 133400 | EVENT | |||
LOSS | 10 | EVENT | 100 | EVENT | 65 | EVENT | 648 | EVENT | ||
CVP | 13340 | EVENT | 133400 | EVENT | 10 | EVENT | 100 | EVENT | ||
ESP | 65 | EVENT | 648 | EVENT | 10 | EVENT | 100 | EVENT | ||
SESP | 10 | EVENT | 100 | EVENT | 10 | EVENT | 100 | EVENT | ||
UASP | 10 | EVENT | 100 | EVENT | 10 | EVENT | 100 | EVENT | ||
SASP | 10 | EVENT | 100 | EVENT |
|
|
|
|
| |
|
| CVs PER SESL: 1544 | CVs PER SESP: 330 | CVs PER |
| |||||
Press
*Indicates valid range of values for selected field. See Table
Figure
© 2000, ADC Telecommunications, Inc.