ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

TAD-101

Page 1 of 9

SPECIFICATIONS

Summary: This TAD shows technical specifications for the Soneplex Broadband system with MPU Version 5 software in Table 101-1(System Specifications), Table 101-2(DS3 MUX Power), Table 101-3(DLX Power), Table 101-4(C1 HLXC Power), Table 101-5(Version D and E HLXC Power), Table 101-6(ODS2 Power), Table 101-7(A2 RLX Power), and Table 101-8(Version B RLX / RLXIOR Power).

Table 101-1. Soneplex Broadband System (V5) Specifications

PARAMETER

SPECIFICATION

REMARKS

Dimensions

 

 

Chassis (H W D)

10 21.5 12 inches

 

 

(25.4 54.6 30.5 cm)

 

 

 

 

Environment

 

 

Operating Relative Humidity

5% to 95%

No condensation

 

 

 

Operating Temperature

–40°F to 149°F (–40°C to 65°C)

 

 

 

 

Storage Temperature

–40°F to 158°F (–40°C to 70°C)

 

 

 

 

Power

 

 

Input Voltage Range

–42.5 to –56.5 VDC

A and B feed

 

 

 

Consumption (–48 VDC):

 

 

APU

7.5 watts maximum

 

 

 

 

MPU

5 watts maximum

 

 

 

 

DS3 MUX

See Table 101-2

Per module

 

 

 

DLX

See Table 101-3

Per module

 

 

 

C1 HLXC

See Table 101-4

 

 

 

 

Version D and later HLXCs

See Table 101-5

 

 

 

 

B1 HLXR

9.9 watts

Simplex current enabled

 

8.3 watts

Simplex current disabled

 

 

 

Version D and later HLXRs,

9 watts

Simplex power enabled (D1, D2,

HLXR 3192

 

D2A-SP, D3, D3A, D3B HLXRs

 

 

only)

 

 

 

 

4 watts

Simplex power disabled (D2A,

 

 

D4, D4A, D4B, and Version E

 

 

HLXRs; and HLXR 3192 only)

 

 

 

ODS2

See Table 101-6

 

 

 

 

A2 RLX

See Table 101-7

 

 

 

 

Version B RLX / RLXIOR

See Table 101-8

 

 

 

 

TAU

2 watts maximum

 

 

 

 

RTAU

8.2 watts maximum

 

 

 

 

Maximum Power

Determined by configuration

 

 

 

 

 

 

(continued)

 

 