ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

TAD-101

Page 2 of 9

Table 101-1. Soneplex Broadband System (V5) Specifications, continued

PARAMETER

SPECIFICATION

REMARKS

DS3 Interface (DS3 MUX)

 

 

 

 

DS3 Input Level

+5.7 dBm to –7.3 dBm

 

 

 

 

 

 

DS3 Transmit Power Level

–1.8 to +5.7 dBm

 

 

 

 

 

 

Format

Bipolar, Return to Zero

 

 

 

 

 

 

Impedance

75 ohms (nominal)

With splitter/combiner

 

 

 

 

 

Line Code

B3ZS

 

 

 

 

 

 

Line Rate

44.736 Mbps ± 20 ppm

 

 

 

 

 

 

Maximum Span

450 ft. to cross-connect facility

 

 

 

 

 

 

DS3 Interface (D1 DS3 MUX)

 

 

 

 

DS3 Input Level

+5.7 dBm to –7.4 dBm

 

 

 

 

 

 

DS3 Transmit Power Level

–1.8 to +5.7 dBm

 

 

 

 

 

 

 

 

Format

Bipolar, Return to Zero

 

 

 

 

Impedance

75 ohms nominal

With splitter/combiner

 

 

 

Line Code

B3ZS

 

 

 

 

Line Rate

44.736 MHz ± 20 ppm

 

 

 

 

Maximum Span

450 ft. to cross-connect facility

 

 

 

 

 

 

DLX Module

 

 

 

 

Format

Bipolar, Return to Zero

Transparent to frame format

 

 

 

Input Impedance

100 ohms ± 5%

 

 

 

 

Input Signal Level

0 to –10 dB

 

 

 

 

Line Code

AMI or B8ZS

 

 

 

 

Line Rate

Standard DS1 code at

 

 

1.544 Mbps ± 200 bps (130 ppm)

 

 

 

 

Output Pulse

Per GR-499-CORE, Issue 4

22 AWG ABAM

 

 

 

Output Signal Level

0 dB

 

 

 

 

 

 

C1 HLXC Module

 

 

 

 

Loop Loss

<35 dB @ 196 kHz

135 ohm termination

 

 

 

Loop Types

Two-pair, single or mixed gauges

With or without bridged taps

 

 

 

 

 

Transmission:

 

 

 

 

 

 

 

Format

Two 784 kbps full duplex pairs,

 

 

2B1Q modulation

 

 

 

 

Line Impedance

135 ohms nominal

Balanced

 

 

 

Loop Power Output Voltage

–132 ± 5 VDC

 

 

 

 

Return Loss

>20 dB

40 kHz to 200 kHz

 

 

 

Total Signal Power

+13.5 dBm ± 0.5 dBm

 

 

 

 

 

 

 

 

 

 

(continued)

2-250

© 2000, ADC Telecommunications, Inc.