Page 2 of 9
Table
PARAMETER | SPECIFICATION | REMARKS | ||
DS3 Interface (DS3 MUX) |
|
|
|
|
DS3 Input Level | +5.7 dBm to |
| ||
|
|
|
|
|
DS3 Transmit Power Level |
| |||
|
|
|
|
|
Format | Bipolar, Return to Zero |
| ||
|
|
|
|
|
Impedance | 75 ohms (nominal) | With splitter/combiner | ||
|
|
|
|
|
Line Code | B3ZS |
| ||
|
|
|
|
|
Line Rate | 44.736 Mbps ± 20 ppm |
| ||
|
|
|
|
|
Maximum Span | 450 ft. to |
| ||
|
|
|
|
|
DS3 Interface (D1 DS3 MUX) |
|
|
|
|
DS3 Input Level | +5.7 dBm to |
| ||
|
|
|
|
|
DS3 Transmit Power Level |
|
|
| |
|
| |||
|
|
| ||
Format | Bipolar, Return to Zero |
| ||
|
|
| ||
Impedance | 75 ohms nominal | With splitter/combiner | ||
|
|
| ||
Line Code | B3ZS |
| ||
|
|
| ||
Line Rate | 44.736 MHz ± 20 ppm |
| ||
|
|
| ||
Maximum Span | 450 ft. to |
| ||
|
|
|
|
|
DLX Module |
|
|
|
|
Format | Bipolar, Return to Zero | Transparent to frame format | ||
|
|
| ||
Input Impedance | 100 ohms ± 5% |
| ||
|
|
| ||
Input Signal Level | 0 to |
| ||
|
|
| ||
Line Code | AMI or B8ZS |
| ||
|
|
| ||
Line Rate | Standard DS1 code at |
| ||
| 1.544 Mbps ± 200 bps (130 ppm) |
| ||
|
|
| ||
Output Pulse | Per | 22 AWG ABAM | ||
|
|
| ||
Output Signal Level | 0 dB |
| ||
|
|
|
|
|
C1 HLXC Module |
|
|
|
|
Loop Loss | <35 dB @ 196 kHz | 135 ohm termination | ||
|
|
| ||
Loop Types | With or without bridged taps | |||
|
|
|
|
|
Transmission: |
|
|
|
|
|
|
| ||
Format | Two 784 kbps full duplex pairs, |
| ||
| 2B1Q modulation |
| ||
|
|
| ||
Line Impedance | 135 ohms nominal | Balanced | ||
|
|
| ||
Loop Power Output Voltage |
| |||
|
|
| ||
Return Loss | >20 dB | 40 kHz to 200 kHz | ||
|
|
| ||
Total Signal Power | +13.5 dBm ± 0.5 dBm |
| ||
|
|
|
|
|
|
|
|
| (continued) |
© 2000, ADC Telecommunications, Inc.