Page 4 of 11
Table
DISPLAY | MODULE TYPE | DESCRIPTION |
Lx1 EQPT Fail | QLX | Module Fail, MPU COMM Fail, Laser Degrade, DS1 TX |
|
| LOS or (SISTER COMM Fail and not SISTER MPU |
|
| COMM Fail). |
|
|
|
| HLXC/RLX | BOARD Fail or MPU COMM Fail |
|
|
|
Lx1 EQPT Fail RMT | QLX | Remote Board Fail |
| HLXC/RLX | Not Applicable |
|
|
|
Lx1 Link ALM | QLX | DS2 OPTICAL COMM Fail, DS2 OPTICAL LOS, DS2 |
|
| OPTICAL OOF, or DS2 OPTICAL BER |
|
|
|
| HLXC | LOS, BER or SNR |
|
|
|
| RLX | BER |
|
|
|
Lx1 RMT Link ALM | QLX | REMOTE OPTICAL COMM Fail, REMOTE DS2 |
|
| OPTICAL LOS, REMOTE DS2 OPTICAL OOF, or |
|
| REMOTE OPTICAL DS2 BER |
|
|
|
| HLXC | REMOTE LOSW, DC Loop Continuity (if HLXR is line |
|
| powered), BER, or SNR |
|
|
|
| RLX | Not Applicable |
|
|
|
Dx1 SIG Fail | QLX,/HLXC | DS1 RX LOS |
Dx1 RMT SIG Fail | QLX,/HLXC | Remote DS1 RX LOS |
Lx1 RMT HSKP A/B | QLX | Remote Housekeeping Alarm A reported by QFLC. Remote |
|
| Housekeeping Alarm B is not applicable. |
|
|
|
| HLXC | Remote Housekeeping Alarm A or B reported by an HLXR. |
|
|
|
| RLX | Not Applicable |
|
|
|
Lx1 APS DIS | QLX | Lx1 APS Status or Lx1 APS lockout status |
1- x represents the chassis slot number.
© 2000, ADC Telecommunications, Inc.