FREQ | PSACR | PSNEXT | LCL | ||||||
MHZ | dB/100m | dB/100m | dB/100m | dB/100m | dB/100m | ||||
|
|
|
|
|
|
|
|
|
|
| Max | Spec | Min | Spec | Min | Spec | Min | Spec | Spec |
|
|
|
|
|
|
|
|
|
|
1 | 84.2 | 72.3 | 81.5 | 70.3 | 83.8 | 67.8 | 83.1 | 64.8 | 40.0 |
|
|
|
|
|
|
|
|
|
|
4 | 72.7 | 61.5 | 69.8 | 59.5 | 75.8 | 55.8 | 75.2 | 52.8 | 40.0 |
|
|
|
|
|
|
|
|
|
|
8 | 64.1 | 55.5 | 60.9 | 53.5 | 64.2 | 49.7 | 62.5 | 46.7 | 40.0 |
|
|
|
|
|
|
|
|
|
|
10 | 56.5 | 53.4 | 54.0 | 51.4 | 64.0 | 47.8 | 60.3 | 44.8 | 40.0 |
|
|
|
|
|
|
|
|
|
|
16 | 57.2 | 48.8 | 56.3 | 46.8 | 63.7 | 43.7 | 61.2 | 40.7 | 38.0 |
|
|
|
|
|
|
|
|
|
|
20 | 58.1 | 46.5 | 55.1 | 44.5 | 59.9 | 41.8 | 58.4 | 38.8 | 37.0 |
|
|
|
|
|
|
|
|
|
|
25 | 54.4 | 44.0 | 50.4 | 42.0 | 57.5 | 39.8 | 56.9 | 36.8 | 36.0 |
|
|
|
|
|
|
|
|
|
|
31.25 | 57.5 | 41.5 | 53.8 | 39.5 | 55.4 | 37.9 | 55.6 | 34.9 | 35.1 |
|
|
|
|
|
|
|
|
|
|
62.5 | 40.8 | 32.5 | 39.3 | 30.5 | 52.4 | 31.9 | 50.6 | 28.9 | 32.0 |
|
|
|
|
|
|
|
|
|
|
100 | 35.7 | 25.3 | 33.4 | 23.3 | 52.9 | 27.8 | 51.1 | 24.8 | 30.0 |
|
|
|
|
|
|
|
|
|
|
155 | 23.7 | 17.5 | 22.1 | 15.5 | 45.4 | 24.0 | 43.8 | 21.0 | 28.1 |
|
|
|
|
|
|
|
|
|
|
200 | 25.8 | 12.3 | 23.8 | 10.3 | 46.0 | 21.8 | 43.4 | 18.8 | 27.0 |
|
|
|
|
|
|
|
|
|
|
250 | 14.2 | 7.4 | 12.5 | 5.4 | 43.0 | 19.8 | 41.0 | 16.8 | 26.0 |
|
|
|
|
|
|
|
|
|
|
300 | 11.9 | 3.0 | 9.3 | 1.0 | 43.0 | 18.3 | 39.3 | 15.3 | - |
|
|
|
|
|
|
|
|
|
|
350 | 11.0 | 8.1 | 39.0 | 16.9 | 38.3 | 13.9 | - | ||
|
|
|
|
|
|
|
|
|
|
400 | 7.5 | 3.4 | 37.5 | 15.8 | 35.7 | 12.8 | - | ||
|
|
|
|
|
|
|
|
|
|
450 | 38.9 | 14.7 | 36.2 | 11.7 | - | ||||
|
|
|
|
|
|
|
|
|
|
500 | 39.5 | 13.8 | 35.4 | 10.8 | - | ||||
|
|
|
|
|
|
|
|
|
|
550 | - | - | 31.9 | - | 32.3 | - | - | ||
|
|
|
|
|
|
|
|
|
|
600 | - | - | 31.2 | - | 29.2 | - | - | ||
|
|
|
|
|
|
|
|
|
|
NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance testing is based on swept frequency measurements. The spec values are based on TIA/EIA-
O r d e r i n g I n f o r m a t i o n
Description | Catalog Number |
|
|
1000 foot reel, 41lbs 61kg | |
|
|
NOTES: XX = Jacket color - BL = Blue, WT = White, GY = Gray |
|
Website: www.adc.com
From North America, Call Toll Free:
Fax:
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA
Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
104744AE 4/08 Revision © 2008, 2007 ADC Telecommunications, Inc. All Rights Reserved