ADC MMX 8000 Multi-Sector WiMAX Base Station Specifications, FlexWave MMX, w w w . a d c . c o m

Models: MMX 8000

1 4
Download 4 pages 32.33 Kb
Page 3
Image 3
Multi-Sector WiMAX Base Station

9 / 0 8 • 1 0 6 9 8 0 A E   FlexWave­MMX 8000

FlexWaveMMX 8000

Multi-Sector WiMAX Base Station

Specifications

Radio and Modem

 

Frequency:

MMX 7113-24: 1350 to 1400 MHz

 

MMX 7114-24: 1400 to 1525 MHz

 

MMX 7125-24: 2496 to 2690 MHz

 

MMX 7135-24: 2496 to 2690 MHz

 

MMX 7137-24: 3600 to 3800 MHz

Radio Access Method:

IEEE802.16-2005 (16e OFDMA)

Compatibility:

WiMAX Forum Wave 2 Profile

Operation Mode:

TDD

Channel Bandwidth:

3.5Mhz, 5 MHz, 7MHz, 10 MHz

Frequency Resolution:

0.25 MHz

Antennas:

Integral Omni External Sector

Number of Antennas Default Antenna:

2

Default Antenna:

Omni

Antennas Connectors:

2x N-Type, 50 Ohm, lightning protected STC-MIMO

Diversity Support:

2 x 10W; 2 x 45W; 2 x 90W

Output Power per Sector[P1dB]:

Type 10W: 30 dBm +/-1dB maximum

Output Power (average):

Type 45W: 36 dBm +/-1dB maximum

FFT/Modulation:

512/1024 FFT points; QPSK, 16QAM, 64QAM

FEC:

Convolution Code and Turbo Code

TPC:

15dB

Synchronization:

GPS or IEEE1588 (optional)

Network Interfaces

 

Network:

40.5-60VDC 10/100BaseT Half/Full Duplex IEEE 802.3 CSMA/CD

 

Fiber Optic - optional

ASN GW Compatibility:

WiMAX Forum R6 Profile C Compatible with CISCO ASN-GW

Configuration and Management

 

Management:

SNMP

SNMP Agent:

SNMP ver 2 client: MIB II (RFC 1213) Private Wi-Max MIBs

Software Upgrade:

FTP

Remote Configuration:

FTP

Mechanical

 

Dimensions [HxWxD]:

60cm x 27cm x 10cm/23.6" x 10.6" x 4"

Weight:

<15Kg / 33 lbs

Power Interface

 

Input:

48VDC

Power Consumption:

Type 10W: 75Watt maximum Type 45W: 140Watt maximum

Environmental

 

Operating Temperature:

-40°C to +55°C

Operating Humidity:

5%-95% non condensing, weather protected

Standards Compliance

 

EMC:

FCC Part 15, Subpart B, Class A ETSI EN 301489-1/4

Safety:

TUV-UL 60950-1 IEC 60950-1

Environmental:

ETS 300 019:

 

Part 2-1 T 1.2 & Part 2-2 T 2.3

 

Part 2-4 T 4.1E

 

IP66

Immunity:

EN61000-4-2

 

EN61000-4-4

 

EN61000-4-5

Radio:

FCC Part 27 ETSI EN302 326

w w w . a d c . c o m