ADCP-61-814 Issue 1 April 1999

Table 2. PWR AVIS Technical Specifications, continued

PARAMETER

SPECIFICATION

 

Electrical Performance (Amplifier Card)

 

 

 

 

 

Gain

 

 

0 dB amp card

0±1 dB,

5 – 100 MHz

10 dB amp card

10±1 dB,

5 – 100 MHz

20 dB amp card

20±1 dB,

5 – 50 MHz

 

 

Reverse Isolation

<-50 dB, 5-50 MHz

 

<-40 dB, 50-100 MHz

 

 

 

Impedance

75 ohms nominal

 

 

 

 

Return Loss

 

 

Input

<-30 dB, 5-50 MHz

 

<-20 dB, 50-100 MHz

Output

<-20 dB, 5-50 MHz

 

<-15 dB, 50-100 MHz

 

 

 

Noise Figure

 

 

0 dB

25 dB Typical

 

10 dB

18 dB Typical

 

20 dB

17 dB Typical

 

 

 

 

CSO (typical) 6 channels, T7-T12,

 

 

@ 30 dBmV per channel output

60 dBc Typical

 

0 dB

 

10 dB

60 dBc Typical

 

20 dB

50 dBc Typical

 

 

 

 

CTB (typical) 6 channels, T7-T12,

 

 

@ 30 dBmV per channel output

 

 

0 dB

70 dBc Typical

 

10 dB

70 dBc Typical

 

20 dB

70 dBc Typical

 

 

 

 

Alarm Contacts

Normally open

 

 

 

 

Environmental

 

 

 

 

Operating Temperature

32–122 F (0–50 C)

 

 

Humidity Range

20–90% non-condensing

 

 

 

Page 11