Front Panel152-402-145-02, Issue 2
| Table 1. |
|
|
Function | |
|
|
List number | Identifies the list number of the |
|
|
Alarm (ALM) LED | Shows alarm states for remote and local Loss of Signal (LOS). |
Steady red | Indicates a Loss of Signal (LOS) condition at the T1 input of the |
Blinking | Indicates an LOS condition at the T1 input of the |
|
|
Loop LED | Displays HDSL2 Loop condition. |
Steady green | Indicates HDSL2 loop is in sync. |
Blinking once | Indicates the HDSL2 loop is trying to acquire sync. |
per second |
|
Blinking 4 times | Indicates a margin alarm condition on the HDSL2 loop. |
per second |
|
Blinking 10 times | Indicates a Cyclic Redundancy Check (CRC) error on the HDSL2 loop. |
per second |
|
OFF | Indicates no activity on the HDSL2 loop. |
|
|
DS1 Framing LEDs (ESF and SF) | Indicates framing patterns. If DS1 signals are not detected, the ESF and SF LEDs will not light. |
ESF LED = Steady green | Indicates Extended Super Frame (ESF). The LED blinks once per second when a frame error |
| occurs. |
SF LED = Steady green | Indicates Super Frame (SF). The LED blinks once per second when a frame error occurs. |
OFF | Indicates unframed or no signal. |
|
|
DS1 Line Code LEDs (B8ZS and | Indicates DS1 code options. If DS1 signals are not detected, the ESF, SF, B8ZS, and AMI LEDs |
AMI) | will not light. |
B8ZS LED =Steady green | Indicates that the DS1 line code option is set to Bipolar with |
| blinks once per second when a string of excessive zeros is detected. |
AMI LED = Steady green | Indicates that the user DS1 line code option is set to Alternate Mark Inversion (AMI). This LED |
| blinks once per second when a Bipolar Violation (BPV) is detected. |
|
|
Loopback (LPBK) LED | Shows loopback states to and from the network and to and from the Customer Interface (CI). |
Steady yellow | Indicates Network Remote (NREM) loopback, SmartJack (SMJK) loopback, or Transmit Loss of |
| Signal (TLOS) loopback. |
Blinking once | Indicates Customer Local Loopback (CLOC) loopback state. |
per second |
|
Blinking 4 times per second | Indicates the |
|
|
Loopback pushbutton | Activates or deactivates a dual loopback (NREM and CLOC) at the |
| depressed for more than five (5) seconds. |
|
|
Sealing current (SCURR) switch | Enables sealing current option when |
|
|
DS1 bridging (BRG) jacks | Provides |
| interface. Allows the DS1 payload to be monitored. |
Craft port
Provides bidirectional communication between the unit and an external terminal to allow configuration and performance monitoring through the maintenance terminal screens.
CLEI and ECI bar code label | Provides the |
| the Equipment Catalog Item (ECI) bar code number. |
|
|
Configuration number | The configuration number identifies the version of the product. New configuration numbers |
| usually accompany changes in the last two characters of the CLEI code. |
| The configuration number is found on a small label attached to the PC board. It can also be found |
| as the last two numbers (following the x) of the |
| board. For example: |
|
|
Extraction handle | Used to remove the |
|
|
4 | June 16, 2000 |