Appendix A - Specifications152-402-145-02, Issue 2
LOOP ATTENUATION
Each loop has no more than 35 dB of loss at 196 kHz, with driving and terminating impedances of 135Ω (see Table 13 below).
Table 13. HDSL2 Cable Attenuation Chart
Cable Gauge | Loss at 196 kHz (dB/kft) | Ω per kft |
|
|
|
26/0.4 mm | 3.88 | 83 |
24/0.51 mm | 2.84 | 52 |
22/0.61 mm | 2.18 | 32 |
19/0.91 mm | 1.54 | 16 |
|
|
|
Figure 23 shows the
56 55 Tip
54 | 53 | DS1 IN | |
52 | 51 | ||
|
50 49 Ring
48 47
4645
44 43
42 41
Automatic protection switch power | 40 | 39 |
|
Factory use only | 38 | 37 | Factory use only |
36 35 − 48V
34 33
32 31
30 29
| 28 | 27 | Chassis Ground* |
|
| 26 | 25 |
|
|
| 24 | 23 |
|
|
| 22 | 21 |
|
|
Factory use only | 20 | 19 |
|
|
| 18 | 17 | Circuit Ground |
|
| 16 | 15 | Ring 1 |
|
| 14 | 13 | Ring | HDSL2 |
Automatic protection switch control | 12 | 11 |
| |
| DS1 OUT | |||
| 10 | 9 |
| |
|
| Span | ||
| 8 | 7 | Tip | |
|
| |||
| 6 | 5 | Tip 1 |
|
| 4 | 3 |
|
|
| 2 | 1 Chassis Ground* |
|
Active pins are highlighted in black.
*Chassis Ground may be tied to Earth Ground according to local practice.
Figure 23.
32 | June 16, 2000 |