Radio Frequency Energy

A Category 5 (or better) twisted pair cable must be used to connect the AdderLink units in order to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances.

All other interface cables used with this equipment must be shielded in order to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances.

European EMC directive 89/336/EEC

This equipment has been tested and found to comply with the limits for a class A computing device in accordance with the specifications in the European standard EN55022. These limits are designed to provide reasonable protection against harmful interference. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television reception. However, there is no guarantee that harmful interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to correct the interference with one or more of the following measures: (a) Reorient or relocate the receiving antenna. (b) Increase the separation between the equipment and the receiver. (c) Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. (d) Consult the supplier or an experienced radio/TV technician for help.

FCC Compliance Statement (United States)

This equipment generates, uses and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication.

It has been tested and found to comply with the limits for a class A computing device in accordance with the specifications in Subpart J of part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area may cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference. Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.

Canadian Department of Communications RFI statement

This equipment does not exceed the class A limits for radio noise emissions from digital apparatus set out in the radio interference regulations of the Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le règlement sur le brouillage radioélectriques publié par le ministère des Communications du Canada.

   



60

Page 61
Image 61
Adder Technology AdderLink IP manual Radio Frequency Energy, European EMC directive 89/336/EEC

AdderLink IP specifications

Adder Technology's AdderLink IP is a cutting-edge solution designed to extend and manage KVM (Keyboard, Video, Mouse) signals over IP networks. This innovative technology facilitates the remote access and control of computers and servers, making it an essential tool for organizations that require efficient management of their IT resources.

One of the main features of AdderLink IP is its ability to transmit high-resolution video signals with minimal latency. Supporting resolutions up to 4K at 60Hz, it ensures that users experience clarity and responsiveness that is comparable to direct connections. This capability is crucial for industries such as broadcasting, media production, and any environment where graphics-intensive applications are commonplace.

The AdderLink IP employs advanced digitization techniques to ensure high-quality video transmission over standard IP networks. Its use of H.264 video compression allows for efficient bandwidth usage while maintaining image integrity. With this feature, users can easily adapt to various network conditions without compromising performance.

Another standout characteristic is the support for real-time remote access through a web browser, allowing users to connect to their systems from virtually anywhere in the world. Whether for troubleshooting, maintenance, or system management, the AdderLink IP empowers IT professionals with the flexibility they need to perform their duties effectively. The built-in security protocols ensure that access is both secure and reliable.

Moreover, AdderLink IP is designed to be user-friendly. Configuration and management can be performed via an intuitive web interface, simplifying the setup process for users of all technical skill levels. Compatibility with a range of operating systems and devices further enhances its versatility.

Furthermore, the system supports multi-user access, enabling multiple operators to connect to the same devices simultaneously without conflicts. This functionality is particularly useful in collaborative environments where teams need concurrent access to critical systems.

In summary, Adder Technology's AdderLink IP stands out as a robust solution for KVM over IP needs. With its high-quality video transmission, real-time remote access, ease of use, and enhanced security features, it enables organizations to effectively manage their IT infrastructure, thereby boosting productivity and operational efficiency. As the demand for remote access increases, AdderLink IP remains a pivotal component in the evolution of IT management solutions.