4.9 Cascade query code
The SmartViews use a special ‘query code’ to detect whether or not they are connected to another SmartView. By default your SmartView Pro uses query code AD. SmartView Pro units with firmware versions less than 1.09 and SmartView units with firmware version less than 1.18 used query code EF. This was found to conflict with a small number of other (rare) devices that used the same query code so an alternative query code was provided to ensure compatibility. Either query code may be used but you should make sure that all cascaded SmartView units are set to use the same query code. If any of the cascaded SmartView Pros have firmware versions less than 1.09 then the cascade query code for all the SmartView Pros should be set to EF.
L7 – Cascade query code = AD (default)
L8 – Cascade query code = EF
4.10 Exit configure mode
When you have finished configuring any special options, simply type ‘E’ followed by (enter) to exit configure mode and return to normal operation mode. The attached computers can now be switched on.