- 46 -
Summary of Audible Notification

(Alpha Display Keypads)

SOUND CAUSE DISPLAY

LOUD, INTERRUPTED*
Keypad & External
FIRE ALARM FIRE is displayed; descriptor of zone in alarm is
displayed.
LOUD, CONTINUOUS*
Keypad & External
BURGLARY/AUDIBLE
EMERGENCY ALARM ALARM is displayed; descriptor of zone in alarm is
also displayed.
ONE SHORT BEEP
(not repeated)
Keypad only
a. SYSTEM DISARM
b. SYSTEM ARMING ATTEMPT
WITH AN OPEN ZONE
c. BYPASS VERIFY
a. SYSTEM READY is displayed.
b. The number and descriptor of the open protection
zone is displayed.
c. Numbers and descriptors of the bypassed
protection zones are displayed (one beep is
heard for each zone displayed). Subsequently,
the following is displayed: ZONE BYPASSED
SYSTEM READY.
ONE SHORT BEEP
(once every 40 seconds)
Keypad only
SYSTEM IS IN TEST MODE Opened zone identifications will appear.
ONE BEEP
(once every 40 seconds)
Keypad only
LOW BATTERY AT A
TRANSMITTER LO BAT displayed with description of transmitter.
TWO SHORT BEEPS
Keypad only
ARM AWAY OR MAXIMUM ARMED AWAY or ARMED MAXIMUM displayed.
Red ARMED indicator lit.
THREE SHORT
BEEPS
Keypad only
a. ARM STAY, NIGHT-STAY, OR
INSTANT
b. ZONE OPENED WHILE
SYSTEM IS IN CHIME MODE
a. ARMED STAY or ARMED INSTANT displayed.
Red ARMED indicator lit.
b. CHIME displayed, descriptor of open protection
zone displayed if the [] key is pressed.
RAPID BEEPING
Keypad only
a. TROUBLE
b. MEMORY OF ALARM
a. CHECK displayed; descriptor of troubled
protection zone is displayed.
b. FIRE or ALARM is displayed; descriptor of zone
in alarm is displayed.
c. BELL FAILURE
d. SYSTEM LOW BATTERY
e. LAST 10 SECONDS OF EXIT
DELAY
c. BELL FAILURE or CHECK 70 is displayed.
d. SYSTEM LO BAT or BAT is displayed.
e. ARMED AWAY or ARMED MAXIMUM is
displayed along with You may exit now.
SLOW BEEPING
Keypad only
a. EXIT DELAY WARNING (if
programmed)
b. ENTRY DELAY WARNING
a. ARMED AWAY or ARMED MAXIMUM is
displayed along with You may exit now.
b. DISARM SYSTEM OR ALARM WILL OCCUR is
displayed.
Exceeding the delay time without disarming
causes alarm.
* If a bell is used as external sounder, fire alarm is
pulsed ring;
burglary/audible emergency is
steady ring
.