ADTRAN 3000 Series manual DLP-002, To Begin, Backup Current Configuration to Flash

Models: 3000 Series

1 4
Download 4 pages 49.76 Kb
Page 2
Image 2
DLP-002

DLP-002

NetVanta 3000 Series Routers

 

 

DLP-002

Perform Steps Below in the Order Listed

To Begin

1.Connect to the unit via the Console interface.

2.Perform back-up operations.

If the user wants to continue to use the current configuration and it is not the start-up config, the current configuration should be backed-up prior to upgrading the application image.

Backup Current Configuration to Flash

1.Enter copy running-configstartup-configat the Router# prompt to save the current configuration to flash. You will see Building Configuration… Done. Success! when the download is complete. The current configuration is now saved as the startup configuration file to be executed by the router at each power-up.

Upload the Application Image Using XMODEM

1.Enter copy xmodem flash at the Router# prompt to begin uploading the application image.

2.Enter a filename for the saved image when prompted for the Destination filename.

Application code filenames will have a .biz extension. ADTRAN suggests that the destination filename be the same as the source filename.

An example script of the completed steps is shown below:

copy xmodem flash

Destination filename? ADTRANOS.biz

Begin the XMODEM transfer now.... displays when the router is ready to receive the image. The

character C will scroll across the screen to indicate successful router connection.

Begin the XMODEM upload from the terminal emulation software by using the appropriate command sequence. This may take several minutes. If necessary, refer to the terminal emulation software documentation for help. The NetVanta 3000 Series Routers only support application image loads using files provided by ADTRAN. The NetVanta 3000 Series Routers VT-100 console will be inaccessible during the in-band XMODEM data transfer. (The ADTRAN CLI is still available through previously configured telnet