Electrical connection for the UK
Appliances with 2 wires
WARNING: DOUBLE INSULATED - DO NOT EARTH The appliance must be connected to fixed wiring with a double pole switched fused spur outlet with or without pilot lamp.
We strongly recommend the appliance to be connected only by a qualified electrician who is a member of the NICEIC who will comply with the IEE and any local regulations.
NOTE:
The terminology “DOUBLE POLE” means that both the live and the neutral supplies are switched and disconnected at the same time. The terminations labelled SUPPLY are for the connection for the internal house wiring and the terminations labelled LOAD are for the appliance.
IMPORTANT
The wires of the mains lead supplied with this appliance are coloured in accordance with the following code:
As the colours of the flexible cord of this appliance may not correspond with the coloured markings identifying the termi- nals in the plug, proceed as follows: The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.
The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.
FUSE ON
BLUE | BROWN |
(NEUTRAL) | (LIVE) |
| L |
| LOAD |
N | L |
SUPPLY | |
LOAD | |
| DP 13A, 250V |
N SUPPLY |
5